PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

Dust collector does not
adequately collect dust or
chips; poor performance.

1. Dust collection drum is full.
2. Filter is dirty, drum is full.
3. Dust collector is undersized for

the task.

4. Ducting is at fault.

5. The dust collector is too far away

from the point of suction, or there
are too many sharp bends in the
ducting.

6. The lumber is wet and wood

chips are not flowing through the
ducting smoothly.

7. There is a leak in the ducting, or a

series of small leaks, or too many
open ports.

8. There are not enough open branch

lines at one time, thereby causing
a velocity drop in the main line.

9. The ducting and ports are

incorrectly sized.

10. The machine overall dust

collection design is inadequate.

11. The dust collector is too small for

the dust collection system.

1. Empty collection drum.
2. Clean filter, empty collection drum.
3. Use the correct size duct collector for the type of

machine.

4. Remove dust line from dust collector inlet and

unblock the restriction in the duct line.

5. Relocate the dust collector closer to the point of

suction, and rework ducting without sharp bends.
Refer to Collection System, beginning on

Page 20.

6. Process lumber with less than 20% moisture

content.

7. Rework the ducting to eliminate all leaks. Close

dust ports for lines not being used.

8. Open 1 or 2 more blast gates to different branch

lines to allow the velocity in the main line to
increase.

9. Re-install correctly sized ducts and fittings, contact

machine manufacture for larger port dust collection
shroud. Some machines have poor design for dust
collector use.

10. Use a dust collection nozzle on a stand.

11. Install a larger dust collector to power your dust

collection system.