Electrical, 220v operation, Extension cords – Woodstock SHOP FOX W1816 User Manual
Page 11: Electrical specifications
-9-
W1816 Owner's Manual (Mfg. Since 10/09)
EL
EC
TR
IC
A
L
ELECTRICAL
DO NOT work on your electrical system
if you are unsure about electrical
codes and wiring! Seek assistance from
a qualified electrician. Ignoring this
warning can cause electrocution, fire,
or machine damage.
220V Operation
The Model W1816 is wired for 220V single-phase
operation. The power supply circuit used for this machine
MUST be grounded and rated for the amperage given
below. Never replace a circuit breaker with one of higher
amperage without consulting a qualified electrician to
ensure compliance with wiring codes. This machine must
be connected to a grounded circuit!
A plug is not supplied with this machine. See below for
the recommended plug type for this machine.
If you are unsure about the wiring codes in your area
or you plan to connect your machine to a shared cir-
cuit, you may create a fire or circuit overload hazard—
consult a qualified electrician to reduce this risk.
We do not recommend using an extension cord; however,
if you have no alternative, use the following guidelines:
• Use a cord rated for Standard Service (S).
• Do not use an extension cord longer than 50 feet.
• Ensure that the cord has a ground wire and pin.
• Use the gauge size listed below as a minimum.
Extension Cords
Operating Voltage
Phase
Amp Draw
Min. Circuit Size
Recommended Plug
Extension Cord
220V Operation
Single
22 Amps
30 Amps
NEMA L6-30
10 Gauge, 3 Wire
Figure 1. NEMA L6-30 plug & receptacle.
L6-30 P
L6-30 R
Electrical Specifications
The machine must be properly set up before it is
safe to operate. DO NOT connect this machine to the
power source until instructed to do so in the "Test
Run" portion of this manual.