Sym — system mode register – Samsung S3C8275X User Manual
Page 114
CONTROL REGISTERS
S3C8275X/F8275X/C8278X/F8278X/C8274X/F8274X
4-44
SYM
— System Mode Register
DEH
Set 1
Bit
Identifier
.7 .6 .5 .4 .3 .2 .1 .0
Reset Value
0 – – x x x 0 0
Read/Write
R/W – – R/W
R/W R/W R/W R/W
Addressing Mode
Register addressing mode only
.7
This bit must remain logic "0"
.6–.5
Not used for the S3C8275X/C8278X/C8274X
.4–.2
Fast Interrupt Level Selection Bits
(1)
0 0 0
IRQ0
0 0 1
IRQ1
0 1 0
IRQ2
0 1 1
IRQ3
1 0 0
IRQ4
1 0 1
IRQ5
1 1 0
IRQ6
1 1 1
IRQ7
.1
Fast Interrupt Enable Bit
(2)
0
Disable fast interrupt processing
1
Enable fast interrupt processing
.0
Global Interrupt Enable Bit
(3)
0
Disable all interrupt processing
1
Enable all interrupt processing
NOTES:
1. You can select only one interrupt level at a time for fast interrupt processing.
2. Setting SYM.1 to "1" enables fast interrupt processing for the interrupt level currently selected by SYM.2–SYM.4.
3. Following a reset, you must enable global interrupt processing by executing an EI instruction
(not by writing a "1" to SYM.0).