Mounting, Rack mounting, Mounting -4 – SMC Networks 10/100 User Manual

Page 40: Rack mounting -4

background image

I

NSTALLING

THE

S

WITCH

3-4

Mounting

A TigerSwitch 10/100 unit can be mounted in a standard 13-inch
equipment rack or on a desktop or shelf. Mounting instructions for each
type of site follow.

Installing Optional Modules: Before mounting the switch, be sure you
install any optional modules. If you have purchased optional slide-in
1000BASE-T, 100BASE-FX or GBIC media expansion module, install
these modules now, following the instructions in “Installing an Optional
Module into the Switch” on page 3-7.

Rack Mounting

Before rack mounting the switch, pay particular attention to the following
factors:

Temperature: Since the temperature within a rack assembly may be

higher than the ambient room temperature, check that the
rack-environment temperature is within the specified operating
temperature range. (See page C-2.)

Mechanical Loading: Do not place any equipment on top of a

rack-mounted unit

Circuit Overloading: Be sure that the supply circuit to the rack

assembly is not overloaded.

Grounding: Rack-mounted equipment should be properly grounded.

Particular attention should be given to supply connections other than
direct connections to the mains.