Field-replaceable units in an ex8208 switch, Table 9: frus in an ex8208 switch – Juniper Networks EX8208 User Manual
Page 49

Related Topics
LCD Panel in an EX8200 Switch on page 17
•
•
Understanding Alarm Types and Severity Levels on EX Series Switches
Field-Replaceable Units in an EX8208 Switch
Field-replaceable units (FRUs) are switch components that you can replace at your site.
The switch uses these types of FRUs:
•
Hot-insertable and hot-removable—You can remove and replace these components
without powering off the switch or disrupting the switching function.
•
Hot-pluggable—You can remove and replace these components without powering off
the switch, but the switching function is interrupted until you replace the component.
Table 9 on page 23 lists the FRUs for the EX8208 switch and their types.
Table 9: FRUs in an EX8208 Switch
Type
FRU
Hot-insertable and hot-removable.
Power supplies
Hot-insertable and hot-removable.
Fan tray
Redundant configuration:
•
Master SRE module is hot-pluggable.
•
Backup SRE module is hot-insertable and hot-removable.
Base configuration:
•
Switch must be disabled before the SRE module is removed. See “Taking the SRE
Module Offline in an EX8208 Switch” on page 213.
See “EX8208 Switch Configurations” on page 6.
Switch Fabric and Routing Engine (SRE)
module
Redundant configuration:
•
SF module is hot-insertable and hot-removable.
Base configuration:
•
We recommend that you disable the switch before removing the SF module. See
“Taking the SF Module Offline in an EX8208 Switch” on page 216.
See “EX8208 Switch Configurations” on page 6.
Switch Fabric (SF) module
Hot-insertable and hot-removable.
We recommend that you take the line cards offline before removing them. See
“Removing a Line Card from an EX8200 Switch” on page 218.
8-port SFP+ line card
40-port SFP+ line card
48-port SFP line card
48-port RJ-45 line card
Hot-insertable and hot-removable.
SFP and SFP+ transceivers
23
Copyright © 2010, Juniper Networks, Inc.
Chapter 2: Component Descriptions