Removing a dc power supply from an ex8200 switch – Juniper Networks EX8208 User Manual
Page 235

Figure 81: Removing an AC Power Supply from an EX8200 Switch
Related Topics
Installing an AC Power Supply in an EX8200 Switch on page 150
•
•
AC Power Supply in an EX8200 Switch on page 40
Removing a DC Power Supply from an EX8200 Switch
The DC power supply in an EX8200 switch is a hot-removable and hot-insertable
field-replaceable unit (FRU). You remove DC power supplies from the front of the chassis.
NOTE: EX8208 switches support 2000 W DC power supplies.
EX8216 switches support 3000 W DC power supplies.
CAUTION: Before you remove a power supply, ensure that you have power supplies
sufficient to power the switch left in the chassis. See “Calculating Power Requirements
for an EX8208 Switch” on page 114 and Calculating Power Requirements for an EX8216
Switch.
Before you remove a DC power supply from the switch:
•
Ensure that you understand how to prevent ESD damage. See “Prevention of
Electrostatic Discharge Damage on EX Series Switches” on page 292.
Ensure that you have the following parts and tools available to remove a DC power supply
from an EX8200 switch chassis:
•
Electrostatic discharge (ESD) grounding strap
•
Phillips (+) screwdriver, number 1
209
Copyright © 2010, Juniper Networks, Inc.
Chapter 13: Removing Switch Components