beautypg.com

Connection with serial remote terminals, Connecting the ac adapter, Connection – JVC BR-DV6000U User Manual

Page 21: Line in out monitor out dc12v dv in/out in out off

background image

35

VIDEO

LINE

IN

OUT

MONITOR

OUT

DC12V

DV

IN/OUT

IN

OUT

OFF

AUDIO

REMOTE2

IN

B-Y

R-Y

SYNC IN

TIME CODE

IN

OUT

Y

COMPONENT

OUT

CH 1/3

CH 2/4

IN

OUT

MONITOR

OUT

REMOTE1

TIMER

REC

PLAY

SERIAL

REMOTE

SINGLE

GND

Y/C

DV6000

ONAL

A.DUB

EJECT

COUNTER

AUDIO

INPUT

SELECT

MONITOR OUTPUT

REMOTE

LOCAL

CTL

L

MIX

R

CH-1/2

MIX

CH-3/4

DV

LINE

Y/C

(CPN)

TC
UB

REW

STOP

FF

REC

OPERATE

PLAY

PAUSE

Before connecting the AC adaptor, en-

sure that the TIMER switch is set to
“OFF”. (Refer to “Notes” below.)

1.

Connect the DC cord of the AC adapter to
the DC IN terminal of BR-DV6000.

2.

To prevent accidental disconnection of the
DC cord, fasten the DC cord with a clamp.

1Remove the screw and the clamp shown in

the above figure.

2Insert the DC cord into the clamp and fasten

the clamp unto the unit.

3.

Connect the supplied power cord to the AC
IN terminal of the AC adapter.

4.

Connect the power cord to the power outlet.
• BR-DV6000 is turned on and the OPERATE

indicator lights up in red.
(OPERATE OFF mode)

• If DC IN MODE of the SYSTEM (2/2) Menu

screen is set to “OPE ON”, the OPERATE in-
dicator will light up in green.
(OPERATE ON mode)

Memo

● Even in the OPERATE OFF mode, a small

amount of electricity will still flow into the unit.

● When the unit is in the OPERATE OFF mode,

no operation can be performed except that
of the OPERATE buttons and cassette load-
ing/ejecting.

Notes

• Supply power to BR-DV6000 using the supplied AC adapter. Do

not use other power sources.

• Do not unplug the DC cord and/or the power cord during recording

or playback.

• If the supply voltage is low, an alarm display of “LOW VOLTAGE” is

shown.

• If the TIMER switch is set to REC or PLAY, recording or playback

begins when power is supplied to the DC IN terminal.
When the AC adapter is connected, ensure in particular that the
TIMER switch is not set to REC.
Set the TIMER switch to REC or PLAY only when an external timer
function is used.

LOW VOLTAGE

Alarm message

Supplied power
cord

Supplied AC adaptor

Screw

Clamp

DC cord

DC IN
terminal

TIMER switch

OPERATE indicator

OPERATE button

CONNECTION

– Connecting the AC adapter –

Connect the supplied AC adaptor to BR-DV6000.

34

VIDEO

LINE

IN

OUT

MONITOR

OUT

DC12V

DV

IN/OUT

IN

OUT

OFF

AUDIO

REMOTE2

IN

B-Y

R-Y

SYNC IN

TIME CODE

IN

OUT

Y

COMPONENT

OUT

CH 1/3

CH 2/4

IN

OUT

MONITOR

OUT

REMOTE1

TIMER

REC

PLAY

SERIAL
REMOTE

SINGLE

GND

Y/C

SERIAL OUT

VIDEO

LINE

IN

OUT

MONITOR

OUT

DC12V

DV

IN/OUT

IN

OUT

OFF

AUDIO

REMOTE2

IN

B-Y

R-Y

SYNC IN

TIME CODE

IN

OUT

Y

COMPONENT

OUT

CH 1/3

CH 2/4

IN

OUT

MONITOR

OUT

REMOTE1

TIMER

REC

PLAY

SERIAL
REMOTE

SINGLE

GND

Y/C

IN

OUT

IN

SERIAL

SERIAL OUT

SERIAL

DV: BR-DV6000

VIDEO

LINE

IN

OUT

MONITOR

OUT

DC12V

DV

IN/OUT

IN

OUT

OFF

AUDIO

REMOTE2

IN

B-Y

R-Y

SYNC IN

TIME CODE

IN

OUT

Y

COMPONENT

OUT

CH 1/3

CH 2/4

IN

OUT

MONITOR

OUT

REMOTE1

TIMER

REC

PLAY

SERIAL

REMOTE

SINGLE

GND

Y/C

SERIAL IN

SERIAL OUT

RM-G30

VIDEO

LINE

IN

OUT

MONITOR

OUT

DC12V

DV

IN/OUT

IN

OUT

OFF

AUDIO

REMOTE2

IN

B-Y

R-Y

SYNC IN

TIME CODE

IN

OUT

Y

COMPONENT

OUT

CH 1/3

CH 2/4

IN

OUT

MONITOR

OUT

REMOTE1

TIMER

REC

PLAY

SERIAL

REMOTE

SINGLE

GND

Y/C

SERIAL IN

SERIAL OUT

The following describes examples of serial remote terminal connection.
To use the serial remote terminals, set REMOTE SEL SER of the REMOTE (1/2) Menu screen
to “ON” or “LOC+REM.” (

Page 75)

Connect the wired remote controller RM-G30 to
the SERIAL REMOTE IN terminal.
The commands of the SERIAL REMOTE IN termi-
nal is through-output from the SERIAL REMOTE
OUT terminal. (Only with OPERATE ON)
Multiple VCRs can be operated with RM-G30 by
series connection of the SERIAL REMOTE IN/OUT
terminals.

Start/stop recording with an external switch, e.g., a foot switch.

Connect an external switch, e.g., a foot switch, to
the SERIAL REMOTE IN terminal.
The format of the input signals can be selected
with FOOT SW in the REMOTE (2/2) Menu screen.
(

Page 46)

Dubbing of playback images or sound with other machines using the SERIAL RE-

MOTE OUT terminal.

When BR-DV6000 is in the playback mode, the REC command can be output from the SERIAL
REMOTE OUT terminal (REPLICATION function). With this function, a tape loaded in BR-DV6000
can be dubbed on another unit. For details, refer to

Page 57.

BR-DV6000 can be used as a master or dubbing unit.

Dubbing with 1 VCR.

Operate BR-DV6000 with the wired remote controller RM-G30 (sold separately)

Dubbing with multiple VCRs (Up to 50 VCRs can be controlled comprehensively.)

Memo

If REPLICATION of the SYSTEM
(2/2) Menu screen is set to DV, the
REC command is output from the
DV terminal.

Through-output

Through-output

Foot
switch

(Master unit) BR-DV6000

(Dubbing unit) VCR
with a SERIAL terminal

Video

Sound

Dubbing unit: VCR with SERIAL IN and OUT terminals

SERIAL
terminal

REC command

Signal distributor

CONNECTION

– Connection with serial remote terminals –

(Master unit) BR-DV6000

Video

Sound