Shared ram write/read test failure, Make sure the shared ram address does not conflict, Run the test three times with a delay of at least – IBM 09-0572-000 User Manual

Page 67: Timer test failure, The adapter’s timer is incorrect or the pc timer i, Open adapter for ring operation test failure, Make sure a lobe cable is properly connected to th, Ring operations test failure, Run the group 2 adapter wrap test. if the test is, Make sure a lobe cable is properly connected to a

background image

7-12

C

HAPTER

7: T

ROUBLESHOOTING

Shared RAM Write/Read Test Failure

Make sure the shared RAM address does not conflict with the
adapter ROM or another device.

Run the test three times with a delay of at least 30 seconds
between each test. If the error persists, power down the PC
and try once more.

Timer Test Failure

The adapter’s timer is incorrect or the PC timer is malfunctioning.

Run the test three times with a delay of at least 30 seconds
between each test. If the error persists, power down the PC
and try once more.

Open Adapter for Ring Operation Test Failure

Make sure a lobe cable is properly connected to the adapter
and that the other end of the cable is connected to a DAU,
MAU, or CAU.

Run the test three times with a delay of at least 30 seconds
between each test. If the error persists, power down the PC
and try once more.

Ring Operations Test Failure

Run the Group 2 Adapter Wrap Test. If the test is successful,
the error condition may be related to the ring itself.

Make sure a lobe cable is properly connected to a MAU.

Make sure the selected adapter speed matches the ring
speed.

Try another shared RAM address and size.

Retry the operation after delaying at least 30 seconds.