Adapter Information

Use the View pull-down menu and select Adapter Information,
or press [F8] from the main screen. An example of the Adapter
Information screen is shown in Figure 7-7.

Figure 7-7 Adapter Information

Use the scroll bar to display the full list of parameters on this
screen.

When Tests Fail

If the diagnostic tests fail, the adapter may not be defective.
The problem may be incorrect configuration settings,
configuration settings that conflict with the settings of other
boards, or improper installation.

If any test fails, you can get additional information by
highlighting the test that failed in the Run Tests dialog box
shown in Figure 7-4, and pressing [Enter]. You can also
highlight the command button and press [Enter].
The program notifies you of the error and suggests actions
you can take to solve the problem.

Diagnostic and Manual Configuration Program

Install

Quit

View

Select

A

dapter Information

3Com 3C619C: Token Ring Address = 00608C112233

F1=Help

Test

Token Ring address:
Date of Manufacture:
Division Code:
Product Code:
Configuration Mode:
I/O base address:
Interrupt request level:
Ring speed:
BIOS/MMIO base address:
Boot PROM:
Shared RAM base address:
Shared RAM size:

00600C112233
11/1/95
6
BE
3Com
A20H
3
16 Mbps
CC000H
Not Present
D0000H
64 kB

Cancel

[ENTER]= [

↑↓

]=Scroll

[Alt]+=Execute Function [PgDn]=Page Down [PgUp]=Page Up