S y m p t o m

D i a g n o s i s

C h e c k

One Short Beep

Power Problem

Fuse

Battery Under Load

Battery Connections

3 sec tone, 1 sec silence, 3 sec
tone

Limit Switch Error

Master Input Connections

Power Cable

ORG & GRN, BRN & GRN Terminal
Voltages (5VDC) on each.

Constant Tone

Switch power off and on. If alarm clears, it
is an obstruction alarm.

If alarm does not clear, then it is a low
battery.

Path of gate

Gate for level and plumb

Stall Force Adjustment

Disconnect Safety Devices

Rev Counter

Gate Hits or Drags something
and no longer works.

Gate opener quits working
during windy conditions.

Open or closed too far and
jammed.

Blown Fuse

Fuse

Hear warning buzzer and the
opener does not work.

One gate stops in the middle
of its cycle or operates
intermittently.

Operator arm won’t work or
works slowly or intermittently.

Power Problem

Bad Relay on PCB

Charging with Transformer:

Fuse Connection

Battery Under Load

Battery Connections

Charging Circuit

Transformer

Charging with Solar:

Weather

Solar Panel Placement

Battery Under Load

Charging Circuit

Solar Panel

Output of RED & BLK Master Input Terminals with
wires disconnected while pressing the transmitter.

Opener stops and reverses
itself while attached to the
gate.

Sensing an Obstruction

Path of Gate for something within the path.