background image

Model g0703/g0703p (Mfg. Since 3/12)

-41-

Symptom

possible Cause

possible Solution

loud,
repetitious
noise, or
excessive
vibration
coming from
dust collector.

1. dust collector is not on a flat surface and

wobbles.

2. impeller is damaged and unbalanced.

3. the motor mounting or housing

connections are loose.

4. impeller is loose on the motor shaft.

5. Motor fan cover is dented, causing the

motor fan to hit the cover while spinning.

1. Stabilize the dust collector.

2. disconnect dust collector from power, and inspect

the impeller for dents, bends, loose fins. replace
impeller if any damage is found.

3. Make sure all fasteners on the dust collector are

tight.

4. replace the motor and impeller as a set if the

motor shaft and the impeller hub are damaged.

5. replace motor fan cover.

dust collector
does not
adequately
collect dust
or chips; poor
performance.

1. dust collection bag is full.
2. Filter is dirty.
3. there is a restriction in the duct line.

4. the dust collector is too far away from

the point of suction, or there are too many
sharp bends in the ducting.

5. the lumber is wet and dust is not flowing

through the ducting smoothly.

6. there is a leak in the ducting, or a series

of small leaks, or too many open ports.

7. there are not enough open branch lines at

one time, thereby causing a velocity drop
in the main line.

8. the ducting and ports are incorrectly

sized.

9. the machine dust collection design is

inadequate.

10. the dust collector is too small for the dust

collection system.

1. Empty collection bag.
2. Clean filter.
3. remove dust line from dust collector inlet and

unblock the restriction in the duct line. A plumbing
snake may be necessary.

4. relocate the dust collector closer to the point of

suction, and rework ducting without sharp bends.

5. process lumber with less than 20% moisture

content.

6. rework the ducting to eliminate all leaks. Close

dust ports for lines not being used.

7. open 1 or 2 more blast gates to different branch

lines to allow the velocity in the main line to
increase.

8. reinstall correctly sized ducts and fittings.

9. Use a dust collection nozzle on a stand.

10. install a larger dust collector to power your dust

collection system.

Sawdust being
blown into the
air from the
dust collector.

1. duct clamps or dust collection bag is not

properly clamped and secured.

2. Cylinder or funnel seals are loose or

damaged.

1. re-secure ducts and dust collection bag, making

sure duct and bag clamp are tight.

2. retighten all mounting and sealing points, replace

damaged gaskets.

dust collector operation