troubleshooting

motor & electrical

Symptom

possible Cause

possible Solution

Machine does
not start or a
breaker trips.

1. power supply switched oFF or is at fault.

2. Wall fuse/circuit breaker is blown/tripped.

3. handheld remote controller is at fault.

4. remote receiver is at fault.
5. Motor connection wired incorrectly.
6. Machine circuit breaker has tripped.

7. Wiring is open/has high resistance.

8. power switch is at fault.
9. Circuit board is at fault.
10. Motor is at fault.

1. Ensure power supply is switched

ON; ensure

power supply has the correct voltage.

2. Ensure circuit size is suitable for this machine;

install inlet restrictor, replace weak breaker.

3. replace batteries in handheld remote controller;

stay in line-of-sight view and signal range.
reprogram remote receiver.

4. inspect receiver circuit board; replace if faulty.
5. Correct motor wiring connections.
6. let motor cool, improve ventilation, press

thermal overload button to reset.

7. Check for broken wires or disconnected/

corroded connections, and repair/replace as
necessary.

8. replace faulty switch.
9. replace circuit board.
10. test/repair/replace.

Machine has
vibration or
noisy operation.

1. Motor or component is loose.

2. Motor mount loose/broken.
3. Motor fan is rubbing on fan cover.

4. Motor bearings are at fault.

1. inspect/replace stripped or damaged bolts/

nuts, and re-tighten with thread locking fluid.

2. tighten/replace.
3. replace dented fan cover; replace loose/

damaged fan.

4. test by rotating shaft; rotational grinding/loose

shaft requires bearing replacement.