Motor 110v, Motor 220v – Grizzly 1 1/2 HP Cyclone G0703 User Manual
Page 15
Model g0703/g0703p (Mfg. Since 3/12)
-13-
4. remove the wire nuts indicated in figure 6.
MOTOR 110V
Hot
Neutral
Ground
1
2
3
4
Run
Capacitor
40MFD
250VAC
GND
Start
Capacitor
300MFD
125VAC
G
W
Power
Switch
Circuit
Breaker
Circuit
Board 110V
L2
L1
COM
M2
M1
110 VAC
(Prewired)
L5-30 Plug
(As Recommended)
figure 6. Motor wires at 110V.
remove
remove
5. Connect the motor wires, as shown in
figure 7, with wire nuts. once snug, use
electrical tape to secure each wire nut to the
wires it connect. this will reduce the likeli-
hood of the wire nut loosening during motor
operation.
2
Run
Capacitor
40MFD
250VAC
GND
Start
Capacitor
300MFD
125VAC
Power
Switch
Thermal
Overload
Circuit
Board 220V
L2
L1
COM
M2
M1
4
3
1
MOTOR 220V
Hot
Hot
Ground
6-15 Plug
(Rewired 220V)
220
VAC
G
figure 7. Motor wires repositioned for 220V.
re-Connect
and tighten
re-Connect
and tighten
6. remove the wires connected to the circuit
board, as indicated in
figure 8.
figure 8. location of wires to remove from
circuit board.
2
Run
Capacitor
40MFD
250VAC
GND
Start
Capacitor
300MFD
125VAC
Power
Switch
Circuit
Breaker
Circuit
Board 220V
L2
L1
COM
M2
M1
3
4
1
MOTOR 220V
Hot
Hot
Ground
220
VAC
G
remove
7. remove the three screws indicated by the
short black arrows, see
figure 8, on the
110V circuit board, remove the circuit board,
then secure the 220V circuit board with the
three screws.
8. re-connect the wires removed in step 6 to
the 220V circuit board exactly as they were
connected to the 110V circuit board.
9. re-install the remote control receiver panel
with the screws removed in
step 3.
10. install a nEMA 6-15 plug, according to the
plug manufacturer's instructions included with
the plug. if no instructions were included, use
the wiring diagram on
page 45.