beautypg.com

Grizzly Noise Reduction Kit for Cyclone s 68 User Manual

Grizzly Vacuums

background image

Introduction

These noise reduction kits significantly reduce
the noise level of cyclone dust collectors without
causing efficiency loss.

Installation Instructions

The mufflers are best installed in the outlet hose,
as close to the filter as possible. The installation
consists of removing a section of the outlet hose
and installing the muffler in its place. Wire hose
clamps are provided to secure the muffler to the
outlet hose (see

Figure 1).

To install the muffler:

1. Measure the size of the muffler body (see

Figure 2).

2. Using a felt-tip marker, mark a section of

the outlet hose equal in length to the muffler
body. IMPORTANT: Leave at least 4" of out-
let hose between the filter and the muffler.

3. Remove the portion of the outlet hose marked

in

Step 2.

4. Fit the wire hose clamps over the ends of the

outlet hose and slide them back at least 2"
from the opening.

5. Apply the 3 x 15mm foam tape to the top and

bottom rims of the muffler (see

Figure 2).

6. Fit the ends of the outlet hose completely

over the ends of the muffler.

7. Slide the wire hose clamps down to the end

of the hose near the body, then tighten them
to secure the muffler in place.

MODEL H8165/66/67/68

NOISE REDUCTION KIT

FOR CYCLONE DUST

COLLECTORS

Muffler

Body

Foam

Tape

Foam

Tape

Figure 2.

Size of muffler body.

If you need help installing the noise reducing kit,
call our Tech Support at: (570) 546-9663.

COPyRIghT © NOveMbeR, 2006 by gRIzzLy INdUSTRIAL, INC. RevISed NOveMbeR, 2009.

WaRNINg: NO pORTION OF THIS MaNUaL MaY bE REpRODUCED IN aNY SHapE

OR FORM WITHOUT THE WRITTEN appROvaL OF gRIzzLY INDUSTRIaL, INC.

#TR8803 PRINTed IN TAIWAN

Figure 1.

Noise reducing kit installed.

Wire hose

Clamp

Muffler

Wire hose

Clamp

This manual is related to the following products: