Grounding requirements, Circuit requirements for 220v – Grizzly 1 1/2 HP Cyclone G0703 User Manual
Page 13
Model g0703/g0703p (Mfg. Since 3/12)
-11-
No adapter should be used with the
required plug. If the plug does not fit the
available receptacle, or the machine must
be reconnected for use on a different type
of circuit, the reconnection must be made
by a qualified electrician and comply with all
local codes and ordinances.
figure 4. typical 6-15 plug and receptacle.
Grounding Prong
Current Carrying Prongs
6-15 PLUG
GROUNDED
6-15 RECEPTACLE
Serious injury could occur if you connect
the machine to power before completing the
setup process. DO NOT connect to power
until instructed later in this manual.
grounding requirements
This machine MUST be grounded. In the event
of certain malfunctions or breakdowns, grounding
reduces the risk of electric shock by providing a
path of least resistance for electric current.
figure 3. typical l5-30 plug and receptacle.
Grounding Prong
is Hooked
Hot
Neutral
L5-30 GROUNDED
LOCKING
RECEPTACLE
L5-30
LOCKING
PLUG
figure 2. typical 5-20 plug and receptacle.
Grounding Prong
Hot
Neutral
5-20 PLUG
GROUNDED
5-20 RECEPTACLE
For 110V operation: The plug specified under
“Circuit Requirements for 110V” on the previ-
ous page has a grounding prong that must be
attached to the equipment-grounding wire inside
the included power cord. The plug must only be
inserted into a matching receptacle (see below)
that is properly installed and grounded in accor-
dance with all local codes and ordinances.
For 220V operation: The plug specified under
“Circuit Requirements for 220V” on the previous
page has a grounding prong that must be attached
to the equipment-grounding wire on the included
power cord. The plug must only be inserted into
a matching receptacle (see following figure) that
is properly installed and grounded in accordance
with all local codes and ordinances.
circuit requirements for 220v
nominal voltage .............................. 220v/240v
cycle ..........................................................60 hz
phase ........................................... single-phase
circuit rating ...................................... 15 amps
plug/receptacle ............................. nema 6-15
This machine can be converted to operate on a
220V power supply. The intended 220V circuit
must have a verified ground and meet the require-
ments that follow: