beautypg.com

Grounding requirements, Circuit requirements for 220v – Grizzly 1 1/2 HP Cyclone G0703 User Manual

Page 13

background image

Model g0703/g0703p (Mfg. Since 3/12)

-11-

No adapter should be used with the

required plug. If the plug does not fit the

available receptacle, or the machine must

be reconnected for use on a different type

of circuit, the reconnection must be made

by a qualified electrician and comply with all

local codes and ordinances.

figure 4. typical 6-15 plug and receptacle.

Grounding Prong

Current Carrying Prongs

6-15 PLUG

GROUNDED

6-15 RECEPTACLE

Serious injury could occur if you connect

the machine to power before completing the

setup process. DO NOT connect to power

until instructed later in this manual.

grounding requirements

This machine MUST be grounded. In the event
of certain malfunctions or breakdowns, grounding
reduces the risk of electric shock by providing a
path of least resistance for electric current.

figure 3. typical l5-30 plug and receptacle.

Grounding Prong

is Hooked

Hot

Neutral

L5-30 GROUNDED

LOCKING

RECEPTACLE

L5-30

LOCKING

PLUG

figure 2. typical 5-20 plug and receptacle.

Grounding Prong

Hot

Neutral

5-20 PLUG

GROUNDED

5-20 RECEPTACLE

For 110V operation: The plug specified under
“Circuit Requirements for 110V” on the previ-
ous page has a grounding prong that must be
attached to the equipment-grounding wire inside
the included power cord. The plug must only be
inserted into a matching receptacle (see below)
that is properly installed and grounded in accor-
dance with all local codes and ordinances.

For 220V operation: The plug specified under
“Circuit Requirements for 220V” on the previous
page has a grounding prong that must be attached
to the equipment-grounding wire on the included
power cord. The plug must only be inserted into
a matching receptacle (see following figure) that
is properly installed and grounded in accordance
with all local codes and ordinances.

circuit requirements for 220v

nominal voltage .............................. 220v/240v

cycle ..........................................................60 hz

phase ........................................... single-phase

circuit rating ...................................... 15 amps

plug/receptacle ............................. nema 6-15

This machine can be converted to operate on a
220V power supply. The intended 220V circuit
must have a verified ground and meet the require-
ments that follow: