FT14 and FT14H 10Mb Media Converters Installation and User Guide (09/09)
2
www GarrettCom com
.
.
Maximum Standard Ethernet Segment Lengths:
10BASE-T (twisted pair):
100 m (328 ft)
10BASE-FL Fiber optic :
2.0 km (6,562 ft)
10BASE-FL Single-mode Fiber optic:
10.0 km (32,810ft)
Note for single-mode: HDX collision domain limits may restrict distances to about 5km.
Note: Magnum Media Converters DO NOT support full length Ethernet segments. See
Section 3.2 of this manual for media lengths and segment distance calculations.
Operating Environment:
Ambient Temperature: (0ºC to 50ºC) FT14-Hd,-Hi, FT14S-Hd, Hi
(-40ºC to 55ºC) FT14H-Hd,-Hi, FT14SH-Hd,Hi
(-40ºC to 75ºC) FT14H-9VDC, FT14SH-9VDC, FT14H-
24VDC, FT14SH-24VDC
FT14H-48VDC, FT14SH-48VDC
Cold start down to -25ºC
Storage Temperature: -40ºC to 100ºC (-40ºF to 212ºF)