beautypg.com

Test 8 - diode/resistor, 5 vdc – Guardian Technologies 5209 User Manual

Page 44

background image

WIRING DIAGRAM

30

86

87a

85

87

85

87a

30

86

87

16

15

17

13

16

Figure 6-13. – Starter Contactor Relay

R1

D2

4

14

14

4

3.0 vdc

Figure 6-14. – Testing Field Boost

TEST 8 - dIOdE/RESISTOR

PROCEDURE:
1. Set volt meter to the diode test range.

2. Disconnect the six pin connector from the Voltage Regulator.

3. Disconnect Connector C1. See Page 17 for connector location.

4. Disconnect both wires from the Resistor (R1).

5. Connect the positive meter test lead to the top terminal of the

diode (D1). Connect the negative meter test lead to the bottom
of the diode (D1). See Figure 6-15. INFINITY or an open condi-
tion should be measured.

D2

4

14

WIRE 14

REMOVED

14

4

R1

OL

Figure 6-15. – Diode Test Step 5

6. Connect the positive meter test lead to the bottom terminal of

the diode (D1). Connect the negative meter test lead to the top
of the diode (D1). Approximately 0.5 Volts should be measured.

D2

4

14

WIRE 14

REMOVED

14

4

R1

.5 vdc

Figure 6-16. – Diode Test Step 6

7. Set volt meter to measure resistance.

8. Connect one meter test lead to the top terminal of the diode

(D1). Connect the other meter test lead to the ground terminal.
INFINITY or an open condition should be measured.

9. Connect one meter test lead to one terminal of the resistor

(R1). Connect the other meter lead to the remaining terminal of
resistor (R1). See Figure 6-17. Approximately 25 ohms should
be measured.

section 6
Diagnostic tests

Page 42