beautypg.com

Guardian Technologies 5209 User Manual

Page 37

background image

section 5

tRoublesHooting FloWcHaRts

Page 35

GOOD

BAD

TEST 50 - CHECK

WIRE 167

REPLACE

BAD

REPLACE

BAD

REPLACE

BAD

CORRECT

WIRING

BAD

REPLACE

BAD

REPAIR

OR

REPLACE

REPAIR OR REPLACE

WIRE 14

REPAIR

OR

REPLACE

REPAIR

OR

REPLACE

BAD

REPLACE

REPLACE

GOOD

GOOD

GOOD

(WITH HM)

GOOD

(WITHOUT HM)

GOOD

GOOD

GOOD

BAD

BAD

GOOD

GOOD

FUSE BLOWS

UPON

INSTALLATION

CONTINUITY

MEASURED

FUSE BLOWS

WHEN RUNNING

FUSE IS GOOD BUT

BLOWS WHEN PLACED

TO START

VERIFY START-RUN-STOP

SWITCH IS WIRED CORRECTLY

(SEE FIGURE 6-46, pg. 55)

Problem 10 - 10 Amp Fuse (F1) Blowing

INSTALL NEW
10 AMP FUSE

TEST 43 - CHECK

START STOP

RELAY (SSR)

CHECK FUEL

SOLENOID

(TEST 47)

AND STARTER

CONTACTOR RELAY

(TEST 44)

VERIFY BCR1

AND BCR2 ARE

WIRED

CORRECTLY

TEST 19 - CHECK

BATTERY CHARGE

RECTIFIER 2

(BCR2)

TEST 45 - CHECK

WIRE 15

BAD

TEST 49 - CHECK

WIRE 15B

TEST 46 - CHECK
WIRE 14 CIRCUIT

TEST 8 - DIODE /

RESISTOR

TEST 47 - CHECK

FUEL SHUTOFF

SOLENOID (FSS)

TEST 48 - CHECK

HOURMETER (HM)

IF EQUIPPED