section 3
DescRiption & coMponents

or DPE winding, (c) a center tapped battery charge

winding and (d) a 10 Amp center tapped battery

charge winding. Insulation tests of the stator con-

sist of (a) testing all windings to ground, (b) testing

between isolated windings, and (c) testing between

parallel windings. Figure 3-9 is a pictorial representa-

tion of the various stator leads on units with air-cooled

engine.

TESTING ALL STATOR WINDINGS TO GROUND:
1. Disconnect stator output leads Wire 11 and Wire 44 from the

generator 50A circuit breaker.

2. Remove stator output lead Wire 22 from the neutral terminal

on the back of the 50A outlet.

3. Disconnect the C1 connector from the bottom of the control

panel. See Figure 3-10. The C1 connector is on the right when
facing the control panel.

11

44

22

77A

55

77

6

2

66

66A

55A

44S

11S

Figure 3-9. – Stator Winding Leads

4. Connect the terminal ends of Wires 11, 22, and 44 together.

Make sure the wire ends are not touching any part of the gen-
erator frame or any terminal.

5. Connect the red test probe of the Hi-Pot tester to the joined

terminal ends of stator leads 11, 22, and 44. Connect the black
tester lead to a clean frame ground on the stator can. With tes-
ter leads connected in this manner, proceed as follows:

a. Turn the Hi-Pot tester switch OFF.
b. Plug the tester cord into a 120 volt AC wall sock-

et and set its voltage selector switch to “1500

volts”.

c. Turn the tester switch ON and observe the

breakdown lamp on tester. DO NOT APPLY

VOLTAGE LONGER THAN 1 SECOND. After

one (1) second, turn the tester switch OFF.

If the breakdown lamp comes on during the one-sec-

ond test, the stator should be cleaned and dried. After

cleaning and drying, repeat the insulation test. If, after

cleaning and drying, the stator fails the second test,

the stator assembly should be replaced.
6. Now proceed to the C1 connector ( Female side – Just

removed). Each winding will be individually tested for a short
to ground. Insert a large paper clip (or similar item) into the C1
connector at the following pin locations:

pin

location

Wire

number

Winding

1

11S

Sense Lead Power

2

44S

Sense Lead Power

3

55A

Battery Charge

4

66A

Battery Charge

5

77A

Battery Charge

6

2

Excitation

7

6

Excitation

8

55

10 Amp Battery Charge

9

66

10 Amp Battery Charge

10

77

10 Amp Battery Charge

11

4

(Positive lead to Brush)

12

0

(Negative lead to Brush)

Next refer to Steps 5a through 5c of the Hi-Pot proce-

dure.
Example: Insert paper clip into Pin 1, Hi-Pot from

Pin 1 (Wire 11S) to ground. Proceed to Pin 2, Pin

3, etc. through Pin 10.

PIN

LOCATION

6

PIN

LOCATION

7

PIN

LOCATION

1

PIN

LOCATION

12

2

77A

66A

55A

44S

11S

0

4

77

66

55

6

Figure 3-10. – C1 Connector Pin Location Numbers

(Female Side, Located to the Right When Facing the

Control Panel)

TEST BETWEEN WINDINGS:
1. Insert a paper clip into Pin Location 3 (Wire 55A). Connect

the red tester probe to the paper clip. Connect the black tes-
ter probe to Stator Lead 11. Refer to Steps 5a through 5c of
“TESTING ALL STATOR WINDINGS TO GROUND”.

2. Repeat Step 1 at Pin Location 6 (Wire 2) and Stator Lead 11.