User instructions, Cleaning the studio, Changing the studio batteries – Stovax PR0919 User Manual
Page 6
6
USER INSTRUCTIONS
• Press the ON-OFF button to turn the appliance off
EMERGENCY SHUT OFF
If the batteries fail during use of the fire, move the switch to
the OFF (O) position, Diagram 3
(This switch is set to be ON during normal operation and
must remain ON)
3
AR1933
3. CLEANING THE STUDIO
3.1 Make sure the fire and surrounds are cool before cleaning..
Use:
• A dry cloth or stainless steel product to clean the
polished plate
• A damp cloth for the painted firebox
• A damp cloth to clean the granite/enamelled inner panels
• Use soap and water to clean the glass
3.2 Opening the Glass Window
3.2.1 Steel Frame
[If fitted with a Steel Frame, this needs to be removed
first:
• Lift the frame upwards off its four support brackets,
Diagram 4
4
AR1981
3.3 All models
Using the allen key provided:
• Release the two window locks at the top of the glass
door, Diagram 5. The locks to move from shut to open
towards the outer edges of the glass door, Diagram 5
5
AR1860
• Support the frame and let it fall gently forward
• Open it down to its stop position
When closing the window ensure the window catches are
fully engaged
.
4. CHANGING THE STUDIO BATTERIES
The appliance batteries are located under the polished plate
mounting the wall switch.
• Undo the two screws securing the wall switch and plate
and remove, Diagram 6
6
AR1887
• Correctly position the four new AA size batteries
• Re-assemble the battery holder as shown in Diagram 7
• Ensure the touch pad cable is tucked to the left on fitting
the wall plate back onto the wall
7
AR1932