beautypg.com

Servicing instructions, Replacing parts, Gas valve – Stovax PR0919 User Manual

Page 29: Magnetic safety valve, Control box

background image

29

SERVICING INSTRUCTIONS

REPLACING PARTS

10. GAS VALVE

10.1 To change the gas valve:

• Remove the control assembly, Section 7

• Release the gas inlet pipe, Diagram 18, Arrow A

• Remove the thermocouple from the interrupter block

and release the second thermo current cables

• Release the pilot pipe, Diagram 18, B

• Release the injector feed pipe, Diagram 18, C

• Remove the wire cable, Diagram18, D

• Remove the two screws

The valve can now be freed.

18

AR1873

B

A

C

D

11. MAGNETIC SAFETY VALVE

11.1 To replace the magnetic safety valve:

• Undo the thermocouple from the interrupter block and

remove the two thermo current cables

• Unscrew the interrupter block from the back of the valve

• Undo the silver magnetic valve retaining but on the back

of the valve.

• Gently tap out the mag valve

• Replace with a new unit

• Reassemble in reverse order

12. CONTROL BOX

• Remove the two thermo current cables by removing the

two screws, Diagram 19

• Remove the ignition lead, Diagram 19

• Remove the eight loom wire from the control box,

Diagram 19

19

AR1915

Touch pad
extension
cable

Battery
extension
cable

Eight wire

cable

Ignition lead

Thermo current

cables

• Remove the battery extension cable, Diagram 19

• Remove the touch pad extension cable

The control box can now be replaced.

After replacing the control box you may need to reprogram

the handset:

• Press and hold the reset button on the control box until

you hear two signals. After the second longer signal:

Release the reset button and within 20

seconds

Press the DOWN button on the handset until

you hear an additional long signal

confirming the new code