INSTALLATION INSTRUCTIONS
INSTALLATION
13
AR1905
3.3 STUD WORk INSTALLATION METHOD 2 (EDGE)
For this cool-wall Edge installation, the convected heat of
the fire is channelled into the chimney cavity and vented at
the top.
There is an optional Studio Edge Fixing Kit available for
installing the fire without a frame. STUDIO 1BF CODE No.
8727BFFK01 STUDIO 2BF CODE No. 8727BFFK02
Using the fixing kit:
• Fit the two side and bottom channels to the front flange
of the fire, Diagram 14. There is a deliberate gap at the top
for convected heat
14
AR1912
This now determines the width of your two vertical stud
work supports. The kit has been designed so that
plasterboard can be taken to the three channels, Diagram
14A
14a
AR1934
• Fix the edge of the vertical support to the edge of the
channel
Build the stud work chimney breast to the desired size:
• Ensure all clearances to combustible material are
maintained, 3.1 above
• Decide on flue requirements
• Cut a hole for the flue exit - see Installation Instructions,
Section 2, 2.5.
15
AR1902
• Fit non-combustible board to the stud work above the
fire. This should extend a minimum of 400m above the
appliance.
• Fit plasterboard to the remaining chimney breast front
• Decide on the position for the wall box containing the
batteries and wall switch
• Mount it into the stud work chimney breast connecting
up the wires from the fire, see Stud work Installation with
Frame for wiring detail on previous page
• Connect the flue system and gas services using the
opening in the side of the chimney breast for access.
After commissioning, finish the sides of the chimney breast,
Diagram 16
16
AR1911
The top of the chimney breast must have a minimum
200mm2 vent.
• Apply a plaster finish to the chimney breast
4. FLUE ASSEMBLY
4.1 Two types of flue terminals are available, horizontal and
vertical. To measure for a horizontal terminal:
• Decide on the terminal position
• Measure the height from the top of the appliance to the
centre of the required outlet.
For minimum and maximum flue dimensions see Diagram
17A / 17B.