INSTALLATION INSTRUCTIONS
COMMISSIONING
7. COMMISSIONING
7.1 Complete the Commissioning Checklist at the front of this
manual covering:
• Flue checks
• Gas checks
• Pebble layout - flame picture
For working pressure test, use the access panel at the gas
connection ensuring the burner is in position.
7.2 In the unlikely event that the appliance is receiving
interference from other electronic devices, re-programme
the handset/Control box
Reprogramming handset/Control box
• Remove the battery cover from the handset to see the
four DIP switches. See diagram29
29
AR1935
Each of the four switches can be set to either one of two
positions, in any combination.
To re-code the handset
• Change the combination of how the DIP switches are set.
For example see diagram20
30
AR1936
Once the handset has a new code the control box needs to
be reprogrammed:
To access the control box see Servicing Instructions, Section
7 - Main Control Assembly.
• Press and hold the reset button on the control box until
you hear two signals. After the second longer signal:
•
Release the reset button and within 20
seconds
•
Press the DOWN button on the handset until
you hear an additional long signal