SUMMARY OF AUDIBLE NOTIFICATION

(ALPHA DISPLAY KEYPADS)

SOUND

CAUSE

DISPLAY

LOUD, INTERRUPTED*
Keypad & External

FIRE ALARM

FIRE

is displayed; descriptor of zone in alarm is displayed.

LOUD, CONTINUOUS*
Keypad & External

BURGLARY/AUDIBLE
EMERGENCY ALARM

ALARM

is displayed; descriptor of zone in alarm is also displayed.

ONE SHORT BEEP
(not repeated)
Keypad only

a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE.
c. BYPASS VERIFY

a. DISARMED/READY TO ARM is displayed.
b. The number and descriptor of the open protection zone is displayed.

c. Numbers and descriptors of the bypassed protection zones are displayed
(One beep is heard for each zone displayed). Subsequently, the following is
displayed: DISARMED BYPASS Ready to Arm

ONE SHORT BEEP
(once every 15 seconds)
Keypad only

SYSTEM IS IN TEST MODE

Opened Zone identifications will appear.

ONE BEEP

every 60 sec.

Keypad only

LOW BATTERY AT A TRANSMITTER

LO BAT displayed with description of transmitter.

TWO SHORT BEEPS
Keypad only

ARM AWAY OR MAXIMUM

ARMED AWAY or ARMED MAXIMUM

is displayed. Red ARMED indicator is

lit.

THREE SHORT BEEPS
Keypad only

a. ARM STAY OR INSTANT

b. ZONE OPENED WHILE SYSTEM
IS IN CHIME MODE.
c. ENTRY WARNING**

a. ARMED STAY ZONE BYPASSED or ARMED INSTANT ZONE BYPASSED
is displayed. Red ARMED indicator is lit.
b. CHIME displayed, descriptor of open protection zone will be displayed if the
[

] key is pressed.

c. DISARM SYSTEM OR ALARM WILL OCCUR

is displayed.

RAPID BEEPING
Keypad only

a. TROUBLE
b. AC POWER LOSS ALERT***
c. MEMORY OF ALARM

a. CHECK

displayed. Descriptor of troubled protection zone is displayed.

b. AC LOSS

displayed (may alternate with other displays that may be present).

c. FIRE or ALARM is displayed; descriptor of zone in alarm is displayed.

SLOW BEEPING
Keypad only

a. ENTRY DELAY WARNING**

b. EXIT DELAY WARNING
(if programmed)

a. DISARM SYSTEM OR ALARM WILL OCCUR

is displayed. Exceeding the

delay time without disarming causes alarm.
b. ARMED AWAY or ARMED MAXIMUM

is displayed along with You May

Exit Now

*

If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.

**

Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer.

*** Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power only).