First Alert SA500 User Manual
First Alert Safety
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
This user’s manual contains important information about your Smoke
Alarm’s operation. If you are installing this Smoke Alarm for use by
others, you must leave this manual—or a copy of it—with the end user.
USER’S MANUAL
Printed in Mexico
M08-0148-003
K1
02/07
© 2007 BRK Brands, Inc., a Subsidiary of Jarden Corporation
BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122
All rights reserved. Consumer Affairs: (800) 323-9005
U www.firstalert.com
FIRE SAFETY TIPS
Follow safety rules and prevent hazardous situations: 1) Use smoking
materials properly. Never smoke in bed. 2) Keep matches or lighters
away from children; 3) Store flammable materials in proper containers;
4) Keep electrical appliances in good condition and don’t overload elec-
trical circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys
grease- and debris-free; 6) Never leave anything cooking on the stove
unattended; 7) Keep portable heaters and open flames, like candles,
away from flammable materials; 8) Don’t let rubbish accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately if
they are not working properly. Smoke Alarms that do not work cannot alert
you to a fire. Keep at least one working fire extinguisher on every floor,
and an additional one in the kitchen. Have fire escape ladders or other
reliable means of escape from an upper floor in case stairs are blocked.
BEFORE YOU INSTALL THIS SMOKE ALARM
Important! Read “Recommended Locations for Smoke Alarms”
and “Locations to Avoid for Smoke Alarms” before beginning. This
unit monitors the air, and when smoke reaches its sensing chamber,
it alarms. It can give you more time to escape before fire spreads.
This unit can ONLY give an early warning of developing fires if it is
installed, maintained and located where smoke can reach it, and where
all residents can hear it, as described in this manual. This unit will not
sense gas, heat, or flame. It cannot prevent or extinguish fires.
Understand The Different Type of Smoke Alarms
Battery powered or electrical? Different Smoke Alarms provide
different types of protection. See “About Smoke Alarms” for details.
Know Where To Install Your Smoke Alarms
Fire Safety Professionals recommend at least one Smoke Alarm on
every level of your home, in every bedroom, and in every bedroom
hallway or separate sleeping area. See “Recommended Locations For
Smoke Alarms” and “Locations To Avoid For Smoke Alarms” for details.
Know What Smoke Alarms Can and Can’t Do
A Smoke Alarm can help alert you to fire, giving you precious time to
escape. It can only sound an alarm once smoke reaches the sensor.
See “Limitations of Smoke Alarms” for details.
Check Your Local Building Codes
This Smoke Alarm is designed to be used in a typical single-family
home. It alone will not meet requirements for boarding houses,
apartment buildings, hotels or motels. See “Special Compliance
Considerations” for details.
*All First Alert
®
Smoke Alarms conform to regulatory requirements,
including UL217 and are designed to detect particles of combustion.
Smoke particles of varying number and size are produced in all fires.
Ionization technology is generally more sensitive than photoelectric
technology at detecting small particles, which tend to be produced
in greater amounts by flaming fires, which consume combustible
materials rapidly and spread quickly. Sources of these fires may include
paper burning in a wastebasket, or a grease fire in the kitchen.
Photoelectric technology is generally more sensitive than ionization
technology at detecting large particles, which tend to be produced
in greater amounts by smoldering fires, which may smolder for hours
before bursting into flame. Sources of these fires may include cigarettes
burning in couches or bedding.
For maximum protection, use both types of Smoke Alarms on
each level and in every bedroom of your home.
U
This unit will not alert hearing impaired residents. It is recom-
mended that you install special units which use devices like
flashing strobe lights to alert hearing impaired residents.
U
Do not connect this unit to any other alarm or auxiliary
device. It is a single-station unit that cannot be linked to other
devices. Connecting anything else to this unit may prevent it
from working properly.
U
Unit will not operate without battery power. The Smoke Alarm
cannot work until you install the batteries in the correct
position (Match “+” to “+” and “-” to “-”).
U
This Smoke Alarm has a battery drawer which resists closing
unless batteries are installed.
U
Do not install this unit over an electrical junction box.
Air currents around junction boxes can prevent smoke from
reaching the sensing chamber and prevent the unit from
alarming. Only AC powered units are intended for installation
over junction boxes.
U
Do not stand too close to the unit when the alarm is sounding.
It is loud to wake you in an emergency. Exposure to the horn
at close range may harm your hearing.
U
Do not paint over the unit. Paint may clog the openings to the
sensing chamber and prevent the unit from operating properly.
1
ONELINK
®
BATTERY
OPERATED SMOKE ALARM
WIRELESS OPERATION
First Alert
®
ONELINK
®
Technology is the easy, cost-effective way to
provide your family with whole-home safety. All ONELINK
®
Alarms
communicate with each other without wires or connectors. When one
Alarm sounds, they all sound. This provides your family with an earlier
warning of potential danger, and gives you more time to react.
The communication distance (range) between any two ONELINK
®
Alarms is typically 50 feet (15 meters) inside of a home. Some features
of a home, such as the number of floors, number/size of rooms, furniture
and types of building materials used may reduce the range of the
Alarms. Examples include: suspended ceilings, ductwork, large metallic
appliances (refrigerators) and metal studs. A feature of ONELINK
®
Alarms
is that they operate as a mesh network. All Alarms will repeat any alarm
signal that is received to all other ONELINK
®
Alarms. Interference from
structural conditions can be overcome by adding additional Alarms to
route the wireless signal around obstructions.
U
The range and proper operation of any wireless device will vary
depending on its surroundings. It is very important that each
Alarm is tested individually before and after installation to make
sure that all Alarms respond properly.
U
The ONELINK
®
Alarms are not to be used outdoors or to
transmit between buildings. The Alarms will not communicate
properly under these conditions.
U
Metal objects and metallic wallpaper may interfere with
signals from wireless Alarms. Alarms should be tested after
changes to your home such as remodelling, moving furniture,
and with metal doors opened and closed.
Your First Alert
®
ONELINK
®
Smoke Alarm will automatically communicate
potential fires with all other First Alert
®
ONELINK
®
Smoke Alarms.
FCC NOTICE: This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation. FCC ID: M7U5001L
Changes or modifications not expressly approved by BRK Brands,
Inc. could void the user’s authority to operate the equipment.
UL STANDARD 217
Model
SA500
TABLE OF CONTENTS
Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Before You Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . .1
Wireless Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
How To Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Optional Locking Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
If This Smoke Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
What To Do In Case Of Fire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Using the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
If You Suspect A Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Recommended Locations For Smoke Alarms . . . . . . . . . . . . . . . .4-5
Locations To Avoid For Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . .5
About Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . .5-6
Limitations Of Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6