Run time, History, Thermal – Fortinet 2 SXRC User Manual
Page 53: Overload, Lo-volt, Hi-volt, Service, No history
53
SXRC Remote Control
Opera
tion
RUN TIME
MENU - Here you can view the total time that the
selected amplifier has been powered up since installation in
1/10th of an hour increments.
Once you select the
RUN TIME
menu, a
list of all the amplifiers connected to the
SXRC will be displayed in a scrolling list.
Use the
UP
or
DOWN
keys to scroll
through the list of available amplifiers.
When you have the amplifier selected you
wish to view simply press the
ENT
key to
select it.
The selected amplifier’s total run time
reading will be displayed.
When done viewing the current amplifier’s
run time, press the
ESC
key to return to the
list of available amplifiers.
You can now select another amplifier by using
the
UP
or
DOWN
keys and view its
run time by pressing the
ENT
key.
OR
Press the
ESC
key to return to the SICK
BAY menu and select another function.
s x
x -
- 5
5 0
0 0
0 /
/ 2
2
SYS
MEM-1
GAIN EQ LPF HPF
KOMP
AMP1
LOCK
MEM-2
MEM-3
MEM-4
PHASE
MUTE
AMP2
LEFT
RIGHT
HOME
ENT
ESC
HOME
ENT
ESC
s
s
7 5
5 4
4
h
h o
o u
u r
r
SYS
MEM-1
GAIN EQ LPF HPF
KOMP
AMP1
LOCK
MEM-2
MEM-3
MEM-4
PHASE
MUTE
AMP2
LEFT
RIGHT
HOME
ENT
ESC
HOME
ENT
ESC
HOME
ENT
ESC
HISTORY
MENU - Here you can view the last 5 fault codes and
how long ago they happened versus the run time clock for the
selected amplifier. The following conditions are logged:
THERMAL
- Thermal cutoff protection engaged.
OVERLOAD
- Short circuit protection engaged.
LO-VOLT
- Low voltage protection engaged.
HI-VOLT
- High voltage protection engaged.
SERVICE
- Amp requires service by KICKER.
Once you select the
HISTORY
menu, a
list of all the amplifiers connected to the
SXRC will be displayed in a scrolling list.
Use the
UP
or
DOWN
keys to scroll
through the list of available amplifiers.
When you have the amplifier selected you
wish to view simply press the
ENT
key to
select it.
If there have not been any fault codes
triggered on the selected amplifier, the
display will read
NO HISTORY
.
If there are fault codes listed they are
numbered in order from 1 (the newest) to
5 (the oldest). When a new fault code is
triggered the fault code stack rolls and
the oldest of the 5 is discarded.
s x
x -
- 5
5 0
0 0
0 /
/ 2
2
SYS
MEM-1
GAIN EQ LPF HPF
KOMP
AMP1
LOCK
MEM-2
MEM-3
MEM-4
PHASE
MUTE
AMP2
LEFT
RIGHT
HOME
ENT
ESC
HOME
ENT
ESC
n
n
y
y
o
h
h i
i s
s t
t o
o r
r
SYS
MEM-1
GAIN EQ LPF HPF
KOMP
AMP1
LOCK
MEM-2
MEM-3
MEM-4
PHASE
MUTE
AMP2
LEFT
RIGHT
1
1
= l
l o
o -
- v
v o
o l
l t
t
SYS
MEM-1
GAIN EQ LPF HPF
KOMP
AMP1
LOCK
MEM-2
MEM-3
MEM-4
PHASE
MUTE
AMP2
LEFT
RIGHT