beautypg.com

Caution, 2 replacement of fuse, 3 diagnostics – Furuno NAVpilot NAVpilot-500 User Manual

Page 61

background image

6. MAINTENANCE & TROUBLESHOOTING

6-2

6.2

Replacement of Fuse

The fuse in the processor unit protects the equipment from reverse polarity of
the ship’s mains and equipment fault. If the fuse blows, the power cannot be
turned on.

Contact your dealer about replacement of the fuse.

CAUTION

Use the proper fuse.

Use of a wrong fuse can cause fire or
damage the equipment.

Parts Name

Type

Code No.

Remarks

Fuse

FGMB 4A AC125V

000-119-976 Supplied as spare parts

6.3 Diagnostics

The NAVpilot-500 has a diagnostic function which checks the Processor unit,
Control unit, Heading sensor, Keyboard, LCD and Rudder for proper operation.

To access a diagnostic function, do the following procedure:

1. Press the [MENU] key to show the menu.
2. Rotate the [ENTER] knob to select “TEST”.
3. Press the [ENTER] knob to show the test options window.

PROCESSOR UNIT
CONTROLLER UNIT
HEADING SENSOR
KEYBOARD TEST
SCREEN TEST
RUDDER TEST

OFF

Test options window


4. Rotate the [ENTER] knob to select an option.
5. Press the [ENTER] knob.
6. Rotate the [ENTER] knob to display “NO” next to the test item.
7. Press the [ENTER] knob and then rotate the [ENTER] knob to select “YES”.
8. Press the [ENTER] knob to start the diagnostic test.
9. Press the [MENU] key to finish.