6 5.1.8 setting the temperature alarm, 9 setting the trip distance alarm – Furuno NAVpilot NAVpilot-500 User Manual
Page 57
5. ALARMS
5-6
5.1.8
Setting the temperature alarm
There are five types of water temperature alarms: UNDER, OVER, INSIDE, OUT
OF RANGE and CURRENT RIP. The UNDER and OVER alarms sound when
the water temperature is lower or higher than the value set, the INSIDE and
OUTSIDE alarms sound when the water temperature is within or outside the
range set. For CURRENT RIP, the alarm sounds when the temperature changes
over the value set within a minute.
1. Rotate the [ENTER] knob to select TEMP ALARM from the ALARM menu.
2. Press the [ENTER] knob to show the temp alarm options window.
UNDER
OVER
INSIDE
OUT OF RANGE
CURRENT RIP
OFF
Temp alarm options window
3. Rotate the [ENTER] knob to select the water temperature condition.
When selecting the INSIDE, OUT OF RANGE or CURRENT RIP, set the number
for upper and lower limits, using three digits. For UNDER or OVER, set a value
(Setting range: 0 to 120°F or –20 to 50°C).
4. Press the [ENTER] knob.
5.1.9
Setting the trip distance alarm
The log trip alarm alerts you a defined distance has been reached.
1. Rotate the [ENTER] knob to select TRIP LOG from the ALARM menu.
2. Press the [ENTER] knob to show the log trip options window.
ON
OFF
Log trip options window
3. Rotate the [ENTER] knob to select “ON” or “OFF” as appropriate.
When selecting ON, set appropriate value (Setting range: 0 to 9999 nm/km/sm).
4. Press the [ENTER] knob.