Manual feed timeout – FUJITSU fi-4990C User Manual
Page 89

6-37
Manual Feed Timeout
10 S
<
Manual Feed Timeout
Manual feed timeout
This function sets the waiting time from when the host computer issues a scan command to when
paper is manually put on the hopper. A manual feed timeout error occurs if this time elapses without
putting paper on the hopper.
Remarks
Unit: second
LCD display
Manual Feed Timeout
Options
1 S to 255 S (Default: 30 S)
1.
In <
ENTER
.
The <
Length Check) appears.
2.
Press
repeatedly until “Manual Feed
Timeout” appears in the lower line of the
menu screen.
3.
Press
ENTER
.
The option select screen appears with the
current setting 30 S blinking (blinking indi-
cates “changeable”).
4.
Press
or
.
The displayed option changes (1 S to 255 S).
The value changes in seconds.
5.
When the desired value appears, press
ENTER
to save the change.
The LCD returns to the <
menu screen (Manual Feed Timeout).
<
<
Paper Length Check
<
Manual Feed Timeout
Manual Feed Timeout
30 S
The following is an example of operation when you use this function.
15C6.P65
01.2.17, 5:47 PM
37