beautypg.com

Specifications, Electrical, Ambient – Follett C/E12CI400A User Manual

Page 4: Plumbing, Ventilation clearances, Dry weight

background image

Electrical

220V 60Hz, 1 phase, 6.5 amps
230V 50Hz, 1 phase, 6.5 amps

Furnished with 1.8m (6 ft) power cord

Ambient

Air temp

38°C/100°F Max.

10°C/50°F Min. (Best performance below 80°F/27°C)

Water temp

32°C/90°F Max.

4°C/40°F Min. (Best performance below 70°F/21°C)

Water pressure

5Bar Max./70 P.S.I.

.7 Bar/10 P.S.I. Min.

Plumbing

C/E12CI400A C/E12HI400A

Dispenser drain

3/4" FPT

3/4" FPT

Water inlet

3/8" FPT

3/8" FPT

Note: Water shut-off recommended within 3m (10 ft) of dispenser. Drain to be hard-piped and insulated. Maintain
at least 20mm per 1m run (1/4" per foot) of slope.

Ventilation clearances

6" (153mm) on right side of dispenser, 6" (153mm) at top for ventilation and 12" (305mm) at top recommended for
service.

Note: Do not block right side air intake or top air exhaust

Dry weight

79.4kg (175 lbs)

DRAIN

ICE MACHINE

MAKE-UP WATER

Dispenser front view

Dispenser side view

Specifications

Dispenser rear view

Air
intake

air exhaust

air
intake

power cord

3/4" FPT drain

3/8" FPT
water inlet

407mm

(16")

575mm

(22.625")

826mm

(32.5")

102mm

(4")

458mm

(18")

597mm

(23.5")

4