Specifications, Electrical, Ambient – Follett C/E12CI400A User Manual
Page 4: Plumbing, Ventilation clearances, Dry weight
![background image](/manuals/102957/4/background.png)
Electrical
220V 60Hz, 1 phase, 6.5 amps
230V 50Hz, 1 phase, 6.5 amps
Furnished with 1.8m (6 ft) power cord
Ambient
Air temp
38°C/100°F Max.
10°C/50°F Min. (Best performance below 80°F/27°C)
Water temp
32°C/90°F Max.
4°C/40°F Min. (Best performance below 70°F/21°C)
Water pressure
5Bar Max./70 P.S.I.
.7 Bar/10 P.S.I. Min.
Plumbing
C/E12CI400A C/E12HI400A
Dispenser drain
3/4" FPT
3/4" FPT
Water inlet
3/8" FPT
3/8" FPT
Note: Water shut-off recommended within 3m (10 ft) of dispenser. Drain to be hard-piped and insulated. Maintain
at least 20mm per 1m run (1/4" per foot) of slope.
Ventilation clearances
6" (153mm) on right side of dispenser, 6" (153mm) at top for ventilation and 12" (305mm) at top recommended for
service.
Note: Do not block right side air intake or top air exhaust
Dry weight
79.4kg (175 lbs)
DRAIN
ICE MACHINE
MAKE-UP WATER
Dispenser front view
Dispenser side view
Specifications
Dispenser rear view
Air
intake
air exhaust
air
intake
power cord
3/4" FPT drain
3/8" FPT
water inlet
407mm
(16")
575mm
(22.625")
826mm
(32.5")
102mm
(4")
458mm
(18")
597mm
(23.5")
4