Follett C/E12CI400A User Manual
Page 21
RED
WTR
B-E
B-T
2ND
60M
20M
C
POWER
DR
WHITE
BLACK
YELLOW
WHITE
4
3
2
T.O.L.
START
RUN
GEARMOTOR
COMPRESSOR
R
POTENTIAL
START RELAY
RUN
CAP.
CAPACITOR
START
C
S
2
1
5
T.O.L.
L1
L2
COMP
FAN
DRV
BIN
T-STAT
BIN
SIGNAL
SWITCH
WATER
SENSOR
G
GREEN/YELLOW
GRND IN
ELEC BOX
BROWN
BLUE
WHITE
WHITE
BLACK
BLACK
ORANGE
RED
BLACK
BLA
CK
BLACK
BLACK
VIOLET
VIOLET
ORANGE
ORANGE
RED
RED
BLUE
BLACK
FAN
M
ORANGE
BLA
CK
L
N
HIGH PRESSURE
SAFETY SWITCH
COMPRESSOR
SWITCH
DISPENSER
Diagnostic sequence – Stage 10
If the water level in the float reservoir drops to an unacceptable level, the WTR LED goes out, shutting the
icemaker off. Also, the BT LED comes on, preventing the icemaker from restarting for twenty minutes. If water is
restored, the WTR LED comes back on and flashes to alert the technician that water to icemaker has been lost.
The icemaker restarts at the end of the 20 minute time delay. The flashing WTR LED can be cleared by pressing
the reset button.
Refrigeration cycle
high
pressure
vapor
high
pressure
liquid
low
pressure
liquid
low
pressure
vapor
21
low side
service port
high pressure
switch
high side
service port
compressor
evaporator
thermostatic
expansion
valve
condenser
filter dryer