Refrigeration pressure data, Air-cooled icemaker capacity/24 hrs – Follett C/E12CI400A User Manual
Page 22
22
Ambient Air Temperature ˚F/˚C
Inlet W
ater T
e
mper
ature ˚F/˚C
F
C
50
10
60
16
70
21
80
27
90
32
60
16
468
212
450
204
432
196
410
186
387
176
70
21
417
189
402
182
387
176
369
175
351
159
80
27
366
166
354
161
342
155
328
149
314
142
90
32
317
144
298
135
280
127
271
123
262
119
100
38
268
122
243
110
217
98
214
97
210
95
lbs.
kg.
lbs.
kg.
lbs.
kg.
lbs.
kg.
lbs.
kg.
Air-cooled icemaker capacity/24 hrs.
Table 2 – Compressor data
Compressor current draw
Air-cooled
Ambient air temp.
15.6°C/60°F
21.1°C/70°F
26.7°C/80°F
32.2°C/90°F
37.8°C/100°F
3.2A
3.3A
3.4A
3.5A
3.6A
Locked rotor amps 26.3
Table 3 – Gearmotor data
Gearmotor current
1.3A (nominal)
Locked rotor amps
6.8 amps
Ambient air temperature C
Icemak
er inlet w
ater temper
ature C
C
10
21
32
16
12/1.6
12/1.6
13.1/1.7
27
16.9/2.1
16.8/2.1
18.3/2.2
38
16.3/2.5
22.5/2.6
23.9/2.8
bar
bar
bar
Ambient air temperature F
Icemak
er inlet w
ater temper
ature F
F
50
70
90
60
174/23
174/23
190/25
80
245/31
244/30
265/32
100
237/37
326/38
347/40
psi
psi
psi
Air-cooled Icemaker
Refrigeration Pressure
Discharge Pressure/Suction Pressure
Refrigeration pressure data