Follett C/E12CI400A User Manual
Page 20
20
Diagnostic sequence – Stage 8
If the restart is successful the 20M LED goes off, the 60 minute timer LED (60M) comes on. The 60M LED will
remains on for 60 minutes from restart. A lighted 60M LED indicates the icemaker has experienced an over-torque
condition. If the icemaker runs without problems for 60 minutes and no additional torque errors occur, the 60M
LED goes off and the icemaker continues normal operation.
RED
WTR
B-E
B-T
2ND
60M
20M
C
POWER
DR
WHITE
BLACK
YELLOW
WHITE
4
3
2
T.O.L.
START
RUN
GEARMOTOR
COMPRESSOR
R
POTENTIAL
START RELAY
RUN
CAP.
CAPACITOR
START
C
S
2
1
5
T.O.L.
L1
L2
COMP
FAN
DRV
BIN
T-STAT
BIN
SIGNAL
SWITCH
WATER
SENSOR
G
GREEN/YELLOW
GRND IN
ELEC BOX
BROWN
BLUE
WHITE
WHITE
BLACK
BLACK
ORANGE
RED
BLACK
BLA
CK
BLACK
BLACK
VIOLET
VIOLET
ORANGE
ORANGE
RED
RED
BLUE
BLACK
FAN
M
ORANGE
BLA
CK
L
N
HIGH PRESSURE
SAFETY SWITCH
COMPRESSOR
SWITCH
DISPENSER
RED
WTR
B-E
B-T
2ND
60M
20M
C
POWER
DR
WHITE
BLACK
YELLOW
WHITE
4
3
2
T.O.L.
START
RUN
GEARMOTOR
COMPRESSOR
R
POTENTIAL
START RELAY
RUN
CAP.
CAPACITOR
START
C
S
2
1
5
T.O.L.
L1
L2
COMP
FAN
DRV
BIN
T-STAT
BIN
SIGNAL
SWITCH
WATER
SENSOR
G
GREEN/YELLOW
GRND IN
ELEC BOX
BROWN
BLUE
WHITE
WHITE
BLACK
BLACK
ORANGE
RED
BLACK
BLA
CK
BLACK
BLACK
VIOLET
VIOLET
ORANGE
ORANGE
RED
RED
BLUE
BLACK
FAN
M
ORANGE
BLA
CK
L
N
HIGH PRESSURE
SAFETY SWITCH
COMPRESSOR
SWITCH
DISPENSER
Diagnostic sequence – Stage 9
The second error (2ND) LED comes on if an over-torque condition occurs while the 60M LED is still lit. The 2ND
LED indicates two consecutive over-torque situations have occurred. The icemaker will be shut down at this time
and will not restart unless the manual reset button is depressed.