FortiGate-5050 chassis
FortiGate-5050 Chassis Guide
01-30000-87211-20090106
5
FortiGate-5050 chassis
You can install up to five FortiGate-5000 series boards in the five slots of the
FortiGate-5050 ATCA chassis. The FortiGate-5050 is a 5U 19-inch rackmount ATCA
chassis that contains two redundant DC power connections that connect to -48 VDC Data
Center DC power. The FortiGate-5050 chassis also includes a hot swappable cooling fan
tray. If all five slots contain FortiGate-5005FA2, FortiGate-5001SX, or FortiGate-5001FA2
boards, the FortiGate-5050 chassis provides a total of 40 1-Gigabit ethernet FortiGate
interfaces. If all 5 slots contain FortiGate-5001A boards the FortiGate-5050 chassis
supports 10 1-Gigabit ethernet FortiGate interfaces. If you add FortiGate-ADM-XB2
modules to the FortiGate-5001A boards the FortiGate-5050 chassis supports up to ten
10-Gigabit interfaces
You can also install FortiSwitch-5003A or FortiSwitch-5003 boards in the FortiGate-5050
chassis slots 1 and 2 to provide base backplane communications. Base backplane
communications can be used for HA heartbeat communications and data communications
using FortiGate-5050 base backplane channels. You can add a second FortiSwitch-5003A
or FortiSwitch-5003 board for redundancy. FortiSwitch-5003A boards can also provide
fabric backplane communication using the FortiGate-5050 fabric backplane channels.
You can mix and match any combination of FortiGate-5000 series boards in the
FortiGate-5050 chassis. For example, you could install two FortiGate-5005FA2 boards,
two FortiGate-5001SX boards, and one FortiGate-5001FA2 board. You can also install
FortiController-5208 and FortiGate-5005FA2 boards in a FortiGate-5050 chassis to create
a FortiGate-5005-DIST security system.
Some of the boards installed in a FortiGate-5050 chassis can be operating in a FortiGate
HA cluster and some can be operating as standalone FortiGate units. You can also
operate multiple HA clusters and standalone FortiGate units in a single FortiGate-5050
chassis. You can also use FortiSwitch-5003A or FortiSwitch-5003 boards to operate HA
clusters consisting of FortiGate-5000 series boards installed in multiple FortiGate-5000
chassis. You can also use FortiSwitch-5003A boards for fabric data communication
between chassis.
The FortiGate-5050 chassis also includes 5 rear transition module (RTM) slots. The
FortiGate-5050 chassis supports 10-gigabit fabric channel communication if you have
installed FortiGate-5001A boards with FortiGate-RTM-XB2 modules and one or two
FortiSwitch-5003A boards.
The FortiGate-5050 chassis requires -48VDC Data Center DC power. If DC power is not
available you can install a FortiGate-5053 power converter tray (purchased separately)
with FortiGate-5020/5050 power supplies.
This chapter describes the FortiGate-5050 chassis and includes the following sections:
•
•
•
Physical description of the FortiGate-5050 chassis
•