beautypg.com

Redundant fortigate-5050 power supplies, Redundant fortigate-5053 power converter trays – Fortinet FortiGate 5050 User Manual

Page 18

background image

Connecting the FortiGate-5050 chassis to AC power using the FortiGate-5053 power converter tray

FortiGate-5050 Chassis Guide

18

01-30000-87211-20090106

http://docs.fortinet.com/

Feedback

Figure 10: Non-redundant power for all FortiGate-5050 chassis slots

Redundant FortiGate-5050 power supplies

You can supply redundant power to a FortiGate-5050 chassis by adding a third
FortiGate-5020/5050 power supply to the FortiGate-5053 power converter tray
(see

Figure 11

). If one of the FortiGate-5020/5050 power supplies in the FortiGate-5053

power converter tray fails, the third power supply takes its place without a power
interruption.

Figure 11: 2 + 1 redundant FortiGate-5020/5050 power supplies

Redundant FortiGate-5053 power converter trays

A single FortiGate-5053 power converter tray is usually only connected to one
FortiGate-5050 power input connector. If this power input connector or FortiGate-5053
power converter tray fails or is disconnected the FortiGate-5050 chassis will loose power.
You can supply redundant power to the entire FortiGate-5050 chassis by adding a second
FortiGate-5053 power converter containing two or three FortiGate-5020/5050 power
supplies and connected this FortiGate-5053 power converter tray to the second
FortiGate-5050 power input connector.

Slot 1

Slot 2

Slot 3

1 FortiGate-5053

power convertor tray

2 FortiGate-5020/5050

power supplies

2 x 800W = 1600W

1 FortiGate-5050

chassis

1

2

2

3

4

5

ShMC

1

ShMC

POWER

Hot Swap
Status

Alarm

Minor

Console

Ethernet

Alarm

Reset

Critical

Major

MANAGEMENT

SYSTEM

E1

ZRE

LED MODE

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

E2

OK

CLK

INT

EXT

FL

T

HOT SW

AP

RESET

FL

T

CONSOLE

E T H O

R S 2 3 2

Z R E 0

Z R E 1

Z R E 2

MANAGEMENT

SYSTEM

E1

ZRE

LED MODE

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

E2

OK

CLK

INT

EXT

FL

T

HOT SW

AP

RESET

FL

T

CONSOLE

E T H O

R S 2 3 2

Z R E 0

Z R E 1

Z R E 2

PWR

STA IPM

CONSOLE

USB

1

2

3

4

5

6

7

8

ACC

PWR

STA IPM

CONSOLE

USB

1

2

3

4

5

6

7

8

ACC

PWR

STA IPM

CONSOLE

USB

1

2

3

4

5

6

7

8

ACC

Slot 1

Slot 2

Slot 3

1 FortiGate-5053

power convertor tray

3 FortiGate-5020/5050

power supplies

2 x 800W = 1600W

2 + 1 redundancy

1 FortiGate-5050

chassis

1

2

2

3

4

5

ShMC

1

ShMC

POWER

Hot Swap
Status

Alarm

Minor

Console

Ethernet

Alarm

Reset

Critical

Major

MANAGEMENT

SYSTEM

E1

ZRE

LED MODE

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

E2

OK

CLK

INT

EXT

FL

T

HOT SW

AP

RESET

FL

T

CONSOLE

E T H O

R S 2 3 2

Z R E 0

Z R E 1

Z R E 2

MANAGEMENT

SYSTEM

E1

ZRE

LED MODE

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

E2

OK

CLK

INT

EXT

FL

T

HOT SW

AP

RESET

FL

T

CONSOLE

E T H O

R S 2 3 2

Z R E 0

Z R E 1

Z R E 2

PWR

STA IPM

CONSOLE

USB

1

2

3

4

5

6

7

8

ACC

PWR

STA IPM

CONSOLE

USB

1

2

3

4

5

6

7

8

ACC

PWR

STA IPM

CONSOLE

USB

1

2

3

4

5

6

7

8

ACC