FortiGate-5050 shelf management functions

The shelf managers support redundant operation with automatic switchover. If both shelf
managers are operating normally, one acts as the active shelf manager and the other as
the standby. Usually the primary shelf manager would be the active shelf manager and the
secondary shelf manager would be the standby shelf manager. The shelf managers
monitor each other and either can trigger a switchover if necessary. The active shelf
manager performs all shelf manager functions. If the active shelf manager fails or is
removed, the standby shelf manager takes over all shelf manager functions.

The FortiGate-5050 shelf managers control chassis power up and power down, chassis
power distribution, monitor chassis operating parameters, monitor and control chassis
cooling, and can signal alarms if the chassis encounters problems. All FortiGate-5000
boards installed in the chassis communicate with the shelf managers.

The FortiGate-5050 shelf managers are factory installed. In most cases users do not have
to install or configure the shelf managers.

Each shelf manager has one ethernet interface (ETH 0 and ETH 1). You can connect to
ETH 0 from the shelf manager front panel. ETH 1 connects to the FortiGate-5050
backplane.

The shelf managers are hot swappable. You can remove a shelf manager by opening the
handle until the hot swap LED starts blinking. When the hot swap LED turns solid blue you
can remove the shelf manager from the FortiGate-5050 chassis.

Table 4: Telco alarm connector pin assignment

Pin

Name

Description

1

AMIR+

MinorReset+

2

AMIR-

MinorReset-

3

AMAR+

MajorReset+

4

AMAR-

MajorReset-

5

ACNO

CriticalAlarm - NO

6

ACNC

CriticalAlarm - NC

7

ACCOM

CriticalAlarm - COM

8

AMINO

MinorAlarm -NO

9

AMINC

MinorAlarm - NC

10

AMINCOM

MinorAlarm - COM

11

AMANO

MajorAlarm - NO

12

AMANC

MajorAlarm - NC

13

AMACOM

MajorAlarm - COM

14

APRCO

PwrAlarm - NO

15

APRCOM

PwrAlarm - COM

Shield

Shelf-GND

Shelf Ground