7 waveclean faults, Smart combi, Notice – Henny Penny SMART COMBI FM05-061-A User Manual
Page 65: 7 “waveclean” faults, Cleaning

→ Press the left select button (13) to abort the cleaning program.
NOTICE
For safety reasons, a rinsing process (duration 12 minutes) runs
automatically when WaveClean is cancelled.
5.1.7
“WaveClean” faults
Discolouring may occur to the floor of the cooking chamber underneath
the cartridge. This discolouring is harmless and does not have any
effect on the operation of the unit.
Remedy
Possible cause
Fault
Adjust the unit horizont-
ally
Unit is leaning
●
Cartridges are not
fully emptied
●
Residues of clean-
er/rinsing agent re-
main in the cartridge
●
Rinsing agent is re-
leased at the same
time as the cleaner
Contact customer service
Power failure/unit mal-
function
Adjust holder position
Holder is bent: cartridge
too close to the floor
Contact customer service
Heater not working
Contact customer service
Circulating pump defect-
ive
●
Cooking chamber re-
mains dry
●
Empty outlet filter be-
fore cleaning.
●
Remove heavy soiling
and large particles
manually before
cleaning.
●
Shorten the cleaning
interval.
Cooking chamber too
heavily soiled
Washing water circula-
tion interrupted
●
Cooking chamber is
not clean
Table 8: Causes of faults and troubleshooting
Information regarding
operation with hard water
NOTICE
The unit can be used without softening the water up to a hardness
of 5 °dH. However, water having a total hardness exceeding 0 °dH
contains lime scale, which may form deposits in the cooking chamber.
The amount of lime scale deposited in the cooking chamber is
normally so low that it has no detrimental effect on the operation of
the unit. However, there may be white deposits in the cooking
chamber.
The two-in-one cartridges contain a clear rinsing agent with descaling
properties, which usually prevents these deposits from building up if
the “WaveClean” automatic cleaning function is used regularly.
65
Operating manual
Global Foodservice Solutions
Cleaning
SmartCombi
™