IDK MSD-804FD User Manual
Page 78
MSD-804FD Users Guide (Command Guide)
78
[Table 3.3.11a] Parameters of serial communication settings
@SCF
Set RS-232C port operation
Command
format
@SCF, port, mode
Return value
format
@SCF, port, mode
Parameter
port
: RS-232C connector
0 = All ports, 1 = RS-232C CH1 port, 2 = RS-232C CH2 port
mode
: Operation mode
0 = RECEIVER mode [Default], 1 = TRANSMITTER mode
Example Send
Receive
@SCF,1,1
@SCF,1,1
Set RS-232C CH1 port to TRANSMITTER mode.
Terminated normally.
Related info. 8.10.2 Operation mode
Note
After IP address or serial communication setting is changed, communication may be
disabled. Change environmental settings based on the settings of the MSD.
@GCF
Get RS-232C port operation
Command
format
@GCF
Return value
format
@GCF, rs-232c_1, rs-232c_2
Parameter
rs_232c_1
: Operation mode of RS-232C CH1 port
rs_232c_2
: Operation mode of RS-232C CH2 port
0 = “RECEIVER mode” [Default], 1 = “TRANSMITTER mode”
Example Send
Receive
@GCF
@GCF,1,0
Get operation mode of RS-232C ports.
RS-232C CH1: TRANSMITTER mode; RS-232C CH2:
RECEIVER mode
Related info. 8.10.2 Operation mode
Value
Communication
Value
Communication
Value
Communication
Value
Communication
0 4800 8 N/A 1 12 9600 8 N/A 1
24 19200 8 N/A 1
36 38400 8 N/A 1
1 4800 8 N/A 2 13 9600 8 N/A 2
25 19200 8 N/A 2
37 38400 8 N/A 2
2 4800 8 Odd 1 14 9600 8 Odd 1
26 19200 8 Odd 1
38 38400 8 Odd 1
3 4800 8 Odd 2 15 9600 8 Odd 2
27 19200 8 Odd 2
39 38400 8 Odd 2
4 4800 8 Even 1 16 9600 8 Even 1
28 19200 8 Even 1
40 38400 8 Even 1
5 4800 8 Even 2 17 9600 8 Even 2
29 19200 8 Even 2
41 38400 8 Even 2
6 4800 7 N/A 1 18 9600 7 N/A 1
30 19200 7 N/A 1
42 38400 7 N/A 1
7 4800 7 N/A 2 19 9600 7 N/A 2
31 19200 7 N/A 2
43 38400 7 N/A 2
8 4800 7 Odd 1 20 9600 7 Odd 1
32 19200 7 Odd 1
44 38400 7 Odd 1
9 4800 7 Odd 2 21 9600 7 Odd 2
33 19200 7 Odd 2
45 38400 7 Odd 2
10 4800 7 Even 1 22 9600 7 Even 1
34 19200 7 Even 1
46 38400 7 Even 1
11 4800 7 Even 2 23 9600 7 Even 2
35 19200 7 Even 2
47 38400 7 Even 2