IDK MSD-804FD User Manual
Page 30
MSD-804FD Users Guide (Command Guide)
30
@GNP
Get input position
Command
format
@GNP
Return value
format
@GNP, h_in_1, v_in_1, h_in_2, v_in_2, h_in_3, v_in_3, h_in_4, v_in_4, h_in_5,
v_in_5
, h_in_6, v_in_6, h_in_7, v_in_7, h_in_8, v_in_8, h_in_9, v_in_9
Parameter
h_IN1-9
: Horizontal input position of each input channel
-Horizontal input size to +Horizontal output resolution [Default]: 0
v_IN1-9
: Vertical input position of each input channel
-Vertical input size to +Vertical output resolution [Default]: 0
Note:
If resolutions differ depending on output, the resolution of OUT1 will be the
standard.
Example Send
Receive
@GNP
@GNP,-50,20,0,0,0,0,
0,0,0,0,0,0,0,0,0,0,0,0
Get input display position.
Horizontal and Vertical display positions of
IN1: -50 and 20, respectively; other inputs: 0
for both H and V.
Related info.
8.3.6 Input position
@SNS
Set input size
Command
format
@SNS, ch_1, h_size_1, v_size_1 (, ch_2, h_size_2, v_size_2・・・)
Return value
format
@SNS, ch_1, h_size_1, v_size_1 (, ch_2, h_size_2, v_size_2・・・)
Parameter
ch_1-9
: Input channel
0 = All inputs, 1 = IN1 to 9 = IN9
h_size_1-9
: Horizontal input size
Horizontal output resolution÷4 to Horizontal output resolution×4
[Default]: Horizontal output resolution
v_size_1-9
: Vertical input size
Vertical output resolution÷4 to Vertical output resolution×4
[Default]: Vertical output resolution
Note:
If resolutions differ depending on output, the resolution of OUT1 will be the
standard.
Example Send
Receive
@SNS,1,1925,1084
@SNS,1,1925,1084
Set the horizontal and vertical display
sizes of IN1 to 1925 and 1084,
respectively.
Terminated normally.
Related info.
8.3.7 Input size