@SHD
Set horizontal display period
Command
format
@SHD, ch, h_disp
Return value
format
@SHD, ch, h_disp
Parameter
ch
: Input channel
0 = All inputs, 1 = IN1 to 8 = IN8
h_disp
: Horizontal display period
64 to 2900 ([The total number of horizontal dots - 64] or less)
[Default]: Differs depending on input signals
Example Send
Receive
@SHD,5,1024
@SHD,5,1024
Set horizontal display period of IN5 to 1024.
Terminated normally.
Send
Receive
@SHD,6,1024
@ERR,3
If no signal is input , an error is replied.
Related info.
8.6.3 Horizontal display period
Note
This command is valid only if signals are input.
@GHD
Get horizontal display period
Command
format
@GHD
Return value
format
@GHD, in_1, in_2, in_3, in_4, in_5, in_6, in_7, in_8
Parameter
in_1-8
: Horizontal display of each input channel
64 to 2900 ([The total number of horizontal dots - 64] or less)
[Default]: Differs depending on input signals
Example Send
Receive
@GHD
@GHD,1920,1920,0,1920,
1024,1360,0,1360,0
Get horizontal display lines.
0 is replied to channels without input
signals.
Related info.
8.6.3 Horizontal display period
@SVS
Set vertical start position
Command
format
@SVS, ch, v_start
Return value
format
@SVS, ch, v_start
Parameter
ch
: Input channel
0 = All inputs, 1 = IN1 to 8 = IN8
v_start
: Vertical starting position
10 to 2048 ([The total number of vertical lines - Vertical display period] or less)
[Default]: Differs depending on input signals
Example Send
Receive
@SVS,5,35
@SVS,5,35
Set vertical starting position of IN5 to 35.
Terminated normally.
Send
Receive
@SVS,6,35
@ERR,3
If no signal is input , an error is replied.
Related info.
8.6.4 Vertical start position
Note
This command is valid only if signals are input.