Post Installation System Testing
Once installation is finished, testing is recommended prior to indoctrination of used personnel regarding operation of the system.
Proper installation of the RAX system, and its full range of communication functions, can be tested with three simple steps.
Step 1: Checking Station-to-Station Communication
• Select one station as the key station. Label it "S-1". Label remaining stations "S-2" through "S-n".
•
Call S-2 from S-1 and confirm communication.
•
Call S-1 from S-2 and confirm communication.
•
Repeat process from S-1 to S-n until each station in the system has been tested.
Step 2: Checking Busy Tone signal
Using three stations (S-1, S-2 and S-3)
•
Call S-1 from S-2.
• While S-2 is calling S-1, call S-2 from S-3 to confirm that Busy tone signal is heard.
Step 3: Checking Paging Function (If applicable)
Using S-1, page each zone (touch |j^ and 1,2,3 or 4), then depress Talk button to confirm paging is transmitted
to selected zone (If talkback function is included, release |
t \
Talk button to confirm talkback). To check remote
control operation, touch |
| and zone number button connected to the external devices, and momentarily depress [
t
|
Talk button in handset. Depress button to confirm either continuous or intermittent tone.
Upon completion of the above tests, if any of the remaining communication functions are not found to work as pre
scribed in the Operations Manual, the cause is not due to improper installation. Rather, the Central Exchange Unit must
be checked. If this is the case, an Aiphone Specialist must be consulted.
X L
User Indoctrination
Upon completion of post installation testing and confirmation of the system being fully operable, used personnel should
be indoctrinated as to how to use the system.
The Operation Manual clearly describes all of the communication features of the system. A complete understanding of
the operation of the system by those who will be using it well avoid post installation call backs and related service.
* Special Instructions:
(1)
Please turn on the power switch on the RAX C.E.U. after all the equipment wiring is completed. If intercom sta-
tion(s) would be connected after system powered on, the station(s) would not work properly. Please turn off the
power switch temporarily for about 10 seconds.
(2)
Do not make temporary operation of turning ON and OFF power switch again and again. At least 3 seconds have to
elapse between ON and OFF operations.