(B) RAX Central Exchange Unit Mounting Instructions
1. Central Exchange Unit shall be wall mounted
approximately 1.5 m (5 feet) high from the floor.
2. Install the mounting bracket to the gang boxes
with the provided screws.
Anchor the bracket with the provided screws or
bolts at 4 points.
3. Mount the RAX Central Exchange Unit onto the
bracket, and connect wires for both stations and
AC power line.
4. Replace the covers.
41.75 mm(1-5/8")
TOP VIEW MOUNTING BRACKET
REGULATOR UNIT
MOUNTING 2- OR 4-GANG BOX
HARDWARE (FOR STATION CABLE)
1-GANG BOX
(FOR AC POWER LINE)
GROUNDING
WIRE
ANCHORING
POINTS
(2)
FOR RAX UNIT
CONNECTING
WIRES
FOR STATIONS
RAX-24 TERMINAL LOCATIONS
WALL
SCREW
CZl
-10 cm or more
(4")
For easy instaliation/removal of the
cover, leave space of 10 cm (4")
or more between a side of RAX
unit and the wall.