beautypg.com

T1e1 signal status leds – AltiGen MAXCS 7.5 Telephony Hardware User Manual

Page 62

background image

Vision Access Boards

56

Telephony

Hardware

Manual

T1E1 Signal Status LEDs

The ALTI-VT1E1SM-1PT/ALTI-VT1E1-2 board has two LEDs to show the T1/E1 signal
status. They are located beside each RJ48C connector.

Signal status LEDs

Figure 4. LEDs showing signal status

Green LED

Red LED

Status

ON

OFF

Normal operation

OFF

ON

No signal

ON

Flashing

Frame synchronization is okay, but one of the following

errors has occurred:

Bi-polar violation

Line code violation

System is receiving Yellow alarm from CO

System is receiving Red alarm from CO

Excessive zeros detected

OFF

Flashing

Frame synchronization failed due to one or more of the

following conditions:
Wrong frame type
Wrong line code
Clock not matched, causing massive frame slips
Cable between CSU and T1 port is too long (within 110 feet

is recommended)
CRC checksum error (E1)

Alternating

Temporary frame slip in normal operation

OFF

OFF

No power to the board