MAX1000 System

48

Telephony

Hardware

Manual

T1E1 Signal Status LEDs

The ALTI-M0404-T1E1 board has two LEDs to show the T1/E1 signal status. The green
LED is labeled "C" and the red LED is labeled "D".

OFF

One of the following is true:

The embedded DSP board is not running.

Access board is not connected to DSP board properly.

DSP board is too busy. Voice signal may be impacted.

LED B

Status

ON

The telephony power supply on the DSP board is supplying
telephony power to the analog extension ports properly.

Normal operation is ON.

OFF

One of the following is true:

Switching software is not running.

The telephony power supply fails to supply power.

LED C

(Green)

LED D

(Red)

Status

ON

OFF

Normal operation

OFF

ON

No signal

On

Flashing

Frame synchronization is okay, but one of the following
errors has occurred:

Bi-polar violation

Line code violation

System is receiving Yellow alarm from CO

System is receiving Red alarm from CO

Excessive zeros detected.

LED A