beautypg.com

Sm series – General Pump SM Repair Manual User Manual

Page 15

background image

GENERAL PUMP

A member of the Interpump Group

SM SERIES

2.1.2 Assembly of Mechanical Parts

Proceed with assembly following the reverse order indicated in point 2.1.1. The proper sequence is as

follows:

Assemble the rod to the plunger guide. Insert the elastic pin Ø 5 in its hole on the plunger guide (1, fig. 42)

and join the rod to the plunger guide by means of M10x35 screws (1, fig. 43).

Page 15

Ref 300894 Rev.A

06-12

Lock in the rod in correspondence with the two planes with a 36 fork spanner (1, fig. 44) and proceed with

calibration with a torque wrench (1, fig. 45).

Insert the connecting rod in the plunger guide (1, fig. 39) and then insert the spindle (1, fig. 38). Apply the two

shoulder Seeger rings (1, fig. 37).

Assembly has been carried out properly if the connecting rod foot, plunger guide

and spindle rotate freely.

Separate the caps from the half supports. Proper coupling can be verified by the numbering on the side

(1, fig. 40). After having checked casing cleaning, proceed with assembly of half support/plunger guide unit

inside casing rods (1, fig. 33).

Insertion of the half support/plunger guide cunit in the casing must be made with

the half bearings set in the direction in which numbers are visible from above.