Example of applying a filter to a lan interface – Lucent Technologies 6000 User Manual
Page 565

Defining Static Filters
Applying a filter to an interface
MAX 6000/3000 Network Configuration Guide
15-29
Following is a RADIUS profile in which the TOS filter is specified within the profile:
jfan-pc Password="johnfan"
Service-Type=Framed-User,
Framed-Protocol=PPP,
Framed-IP-Address=10.168.6.120
Framed-IP-Netmask=255.255.255.0
Ascend-Filter="iptos in dstip 10.1.1.1/32 dstport=23 precedence
010 type-of-service latency"
Note:
Filter specifications cannot contain newline indicators. The preceding example shows
the specification on two lines for printing purposes only.
Example of applying a filter to a LAN interface
Ethernet interfaces are connected routes, so call filters are not applicable. However, you can
apply a data filter that affects which packets are allowed to reach the Ethernet or leave the
Ethernet for another interface. A filter applied to an Ethernet interface takes effect
immediately. If you change the Filter profile definition, the changes apply as soon as you save
the Filter profile.
Note:
Use caution when applying a filter to the Ethernet interface. You could inadvertently
render the MAX unit inaccessible from the local LAN.
The following parameters apply to a filter in a local network interface:
Ethernet
Mod Config
Ether Options
Filter