beautypg.com

Using radius profiles, Using radius profiles -27 – Lucent Technologies 6000 User Manual

Page 275

background image

Configuring Frame Relay

Configuring the MAX as a Frame Relay switch

MAX 6000/3000 Network Configuration Guide

Preliminary January 4, 2001

5-27

Nailed Grp=111

Ethernet

Frame Relay

p130east

Name=p130east

Active=Yes

FR Type=DCE

Nailed Grp=222

The next set of parameters specifies the circuit between the two Frame Relay interfaces:

Ethernet

Connections

max6

Station=max6

Active=Yes

Encaps=FR-Cir

Route IP=No

Encaps options

FR Prof=max

DLCI=100

FR Circuit=frcir1

Ethernet

Connections

p130

Name=p130

Active=Yes

Encaps=FR-Cir

Encaps options

FR Prof=p130east

DLCI=200

FR Circuit=frcir1

Using RADIUS profiles

The following RADIUS frdlink pseudo-user profiles define the datalinks to the MAX and to
the Pipeline 130 (P130-East):

frdlink-max-21 Password="ascend", User-Service=Dialout-Framed-User

Ascend-FR-Profile-Name="max",

Ascend-Call-Type=Nailed,

Ascend-FR-Type=Ascend-FR-DCE,

Ascend-FR-Nailed-Grp=111

frdlink-max-22 Password="ascend", User-Service=Dialout-Framed-User

Ascend-FR-Profile-Name="p130east",

Ascend-Call-Type=Nailed,

Ascend-FR-Type=Ascend-FR-DCE,

Ascend-FR-Nailed-Grp=222

This manual is related to the following products: