Snmp mib for l2tp added, Snmp mib for l2tp added -45 – Lucent Technologies 6000 User Manual
Page 479
Setting Up Virtual Private Networks
SNMP MIB for L2TP Added
MAX 6000/3000 Network Configuration Guide
11-45
ATMP HA RIP=N/A
UDP Port=N/A
Home Network Name=N/A
Pri. Tunnel Server=199.33.
Sec. Tunnel Server=
Password=r3
Client ID=
Tunnel VRouter=
Note:
The Route Line N parameter, formerly in the L2 Tunneling Options profile, is no
longer applicable.
For detailed information about each parameter, see the MAX Reference.
SNMP MIB for L2TP Added
An L2TP MIB, based on the MIB described in the IETF document
draft-ietf-pppext-l2tp-mib-05.txt
, is attached under the Ascend private MIB,
using the identifier tunnelGroup.asndL2tp, as follows:
asndL2tp OBJECT IDENTIFIER ::= { enterprises ascend tunnelGroup 1 }
Note:
Due to internal constraints, several minor changes had to be made to the MIB, and
several variables are not available at this time. This includes the TunnelIfIndex, which has no
related interface in the interface MIB, and some counters, which for the time being are
returning zero.
Parameter
Specifies
Profile type
Whether this profile supports no tunneling, the mobile-client end
of a tunnel, or a tunneling gateway.
Tunnel protocol
The type of tunneling protocol the MAX unit uses to establish a
tunnel.
Max tunnels
The maximum number of tunnels that can be assigned to a Tunnel
Options profile.
ATMP HA RIP
The sending of Routing Information Protocol (RIP) updates to a
mobile client.
UDP Port
The destination UDP port number for ATMP packets.
Home Network Name
The home network that the ATMP Foreign Agent sends to the
ATMP Home Agent.
Pri. Tunnel Server
The IP address or hostname of the primary tunnel server used by
ATMP, PPTP, L2F, and L2TP tunnels.
Sec. Tunnel Server
A secondary tunnel server the unit uses if the primary tunnel
server is unavailable.
Password
The password the MAX unit uses to establish a tunnel.
Client ID
The system name used by a tunnel initiator during tunnel
establishment.
Tunnel VRouter
The type of tunneling protocol the MAX unit uses to establish a
tunnel.