Installing the plenum (if required) – IBM AA-RWF3A-TE User Manual

Page 49

background image

Installing the Plenum (if required)

If installing one of the following SAN switches only, you must install the plenum that

ships in the accessory kit with the rack mount hardware:

4/8 SAN Switch

4/16 SAN Switch

4/32B SAN Switch

To install the plenum:

1.

Place the device (with inner rails attached) on a flat surface, see

Figure 17

.

2.

Obtain the plenum and four 8-32 x .312 Phillips Pan-head SEMs screws from the

accessory kit.

3.

For each inner rail (Left and Right) use one screw hole marked 8 and one screw

hole marked 16 to attach the plenum.

CAUTION:

Verify that the open end of the plenum faces the rear of the switch. For example, when

installed properly you should see the plenum’s air vent holes on one side, and the front

panel of the switch on the other.

SAN Switch installation guide