Weight and physical dimensions, Facility requirements, 23 san switch physical dimensions – IBM AA-RWF3A-TE User Manual
Page 134: 24 facility requirements
Weight and physical dimensions
lists physical properties for the SAN Switches.
Table 23 SAN Switch physical dimensions
4/8 and 4/16
SAN Switches
4/32 SAN Switch
4/64 SAN Switch
4/32B SAN Switch
Height
4.29 cm (1.69
in)
42.44 mm (1.67 in)
2U or 8.6 cm (3.4 in)
1U or 43.5 mm
(1.71 inches)
Width
42.85 cm
(16.87 in)
429 mm (16.89 in)
42.8 cm (16.8 in)
428.75 mm (16.88
inches)
Depth
30.734 cm
(12.10 in)
584.2 mm (23.0 in)
61 cm (24 in)
264 mm (10.39
inches)
Weight
4.0 kg (8.8 lb)
10.16 kg (22.4 lb)
with two power supplies,
three fan assemblies,
and zero SFPs installed
13.7 kg (30.2 lb)
with two power
supplies, three fan
assemblies, and zero
SFPs installed
4.9 kg (10.8 lb)
with two power
supplies/fan
assemblies and zero
SFPs installed
Facility requirements
To ensure correct operation of the switch, the facility where the switch is in use must
meet the requirements shown in
.
Table 24 Facility requirements
Type
Requirements
Electrical
Primary AC input: 100–240 VAC, 2.0 A, 47–63 Hz; switch autosenses input
voltage.
Adequate supply circuit, line fusing, and wire size, as specified by the electrical
rating on the switch nameplate.
Circuit protected by a circuit breaker and grounded in accordance with local
electrical codes.
Thermal
4/8, 4/16, 4/64 and 4/32B SAN Switches: A minimum airflow of 47 cubic
ft/minute available in the immediate vicinity of the switch.
4/32 SAN Switch: A minimum airflow of 24 cubic ft/minute available in the
immediate vicinity of the switch.
Ambient air temperature not exceeding 40 ºC (104 ºF) while the switch is operating.
Cabinet (when
rack mounted)
4/8, 4/16 4/32 and 4/32B SAN Switches:
One rack unit in a 48.3 cm (19 in) cabinet.
134
SAN Switch technical specifications